Toshiba RAS-M16PKVP-E Service Manual page 55

Air-conditioner split type
Hide thumbs Also See for RAS-M16PKVP-E:
Table of Contents

Advertisement

Item
2. Indoor fan motor control
(Continued)
[In starting and in stability]
• Until 12 minutes passed after operation start
FAN AUTO
• When 12 to 25 minutes passed after operation start
and room temp. is 3°C or lower than set temp.
FAN Manual
• Room temp. < Set temp. –4°C
Fan speed level
Fan speed Air flow rate
WF
WE
UH
WD
H
WC
M+
WB
WA
M
W9
W8
L+
W7
L
W6
L–
W5
UL
W4
W3
SUL
W2
W1
Operation flow and applicable data, etc.
In starting
(Table 2) Indoor fan air flow rate (Heating)
RAS-M10PKVP-E
RAS-M13PKVP-E
Fan speed Air flow rate
3
(rpm)
(m
/h)
(rpm)
1140
640
1200
1140
640
1200
1070
590
1100
980
530
1010
900
470
930
850
430
850
810
400
810
710
330
710
710
330
710
650
290
650
650
290
650
650
290
650
650
290
650
560
220
560
420
120
420
• When 12 to 25 minutes passed after operation start
and room temp. is higher than (set temp. –3°C)
• When 25 minutes or more passed after operation start
• Room temp. t Set temp. –3.5°C
RAS-M16PKVP-E
Fan speed Air flow rate
3
(m
/h)
(rpm)
690
1280
690
1280
610
1180
550
1090
490
980
430
900
400
880
330
780
330
710
290
700
290
650
290
650
290
650
220
560
120
420
– 55 –
Description
In stability
RAS-M18PKVP-E
Fan speed Air flow rate
3
(m
/h)
(rpm)
(m
750
1390
805
750
1390
805
670
1290
730
610
1180
655
530
1070
575
470
980
510
450
950
490
380
850
420
330
850
420
320
700
310
290
650
275
290
650
275
290
650
275
220
560
210
120
420
110
3
/h)

Hide quick links:

Advertisement

Table of Contents
loading