Toshiba RAS-M16PKVP-E Service Manual page 45

Air-conditioner split type
Hide thumbs Also See for RAS-M16PKVP-E:
Table of Contents

Advertisement

<Heating> (Continued)
Temperature
No. of
condition
operating
units
Indoor
Outdoor
5 units
20 / —
7 / 6
NOTES :
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor thermometer)
2. Connecting piping condition : 5 meters × 5 units (5m/each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
E
P (MPa)
07
07
07
07
07
2.0 to 2.2
10
07
07
07
07
2.0 to 2.2
13
07
07
07
07
2.0 to 2.2
16
07
07
07
07
2.0 to 2.2
18
07
07
07
07
2.0 to 2.2
10
10
07
07
07
2.0 to 2.2
13
10
07
07
07
2.0 to 2.2
16
10
07
07
07
2.0 to 2.2
18
10
07
07
07
2.0 to 2.2
13
13
07
07
07
2.0 to 2.2
16
13
07
07
07
2.0 to 2.2
18
13
07
07
07
2.0 to 2.2
16
16
07
07
07
2.0 to 2.2
18
16
07
07
07
2.0 to 2.2
10
10
10
07
07
2.0 to 2.2
13
10
10
07
07
2.0 to 2.2
13
13
10
07
07
2.0 to 2.2
16
10
10
07
07
2.0 to 2.2
18
10
10
07
07
2.0 to 2.2
13
13
13
07
07
2.0 to 2.2
16
13
13
07
07
2.0 to 2.2
18
13
13
07
07
2.0 to 2.2
16
16
10
07
07
2.0 to 2.2
18
16
10
07
07
2.0 to 2.2
18
13
13
07
07
2.0 to 2.2
16
16
13
07
07
2.0 to 2.2
18
16
13
07
07
2.0 to 2.2
10
10
10
10
07
2.0 to 2.2
13
10
10
10
07
2.0 to 2.2
16
10
10
10
07
2.0 to 2.2
13
13
10
10
07
2.0 to 2.2
16
13
10
10
07
2.0 to 2.2
16
16
10
10
07
2.0 to 2.2
13
13
13
10
07
2.0 to 2.2
16
13
13
10
07
2.0 to 2.2
13
13
13
13
07
2.0 to 2.2
16
13
13
13
07
2.0 to 2.2
16
16
13
13
07
2.0 to 2.2
10
10
10
10
10
2.0 to 2.2
13
10
10
10
10
2.0 to 2.2
16
10
10
10
10
2.0 to 2.2
18
10
10
10
10
2.0 to 2.2
13
13
10
10
10
2.0 to 2.2
16
13
10
10
10
2.0 to 2.2
18
13
10
10
10
2.0 to 2.2
16
16
10
10
10
2.0 to 2.2
13
13
13
10
10
2.0 to 2.2
16
13
13
10
10
2.0 to 2.2
18
13
13
10
10
2.0 to 2.2
16
16
13
10
10
2.0 to 2.2
13
13
13
13
10
2.0 to 2.2
16
13
13
13
10
2.0 to 2.2
18
13
13
13
10
2.0 to 2.2
16
16
13
13
10
2.0 to 2.2
13
13
13
13
13
2.0 to 2.2
16
13
13
13
13
2.0 to 2.2
– 45 –
Heat exchanger
pipe temperature
Indoor
fan
T1 (°C)
T2 (°C)
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
32 to 35
–2 to 0
High
Compressor
Outdoor
revolution
fan
(rps)
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78
MED
78

Hide quick links: