12-1-4. Microcomputer P.C. Board
1) Remove the electric parts cover screw.
2) Detach the metal electric parts cover.
3) Disconnect the connectors from the P .C. board.
4) Disconnect the solderless terminals from the P .C.
board.
5) Remove the P .C. board.
Electric parts cover detached
Screw
Electric parts
Claw
cover
(2 locations)
Indoor P.C. board
Claw (2 locations)
Fig. 12-1-6
Sub-base
– 123 –
12-1-5. Louver
1) Open the moving panel, and support it with the
panel support.
2) Open the vertical air flow louver.
3) Insert a flathead screwdriver into the gap of the
louver fixture on the right and left ends of the
vertical air flow louver, and turn in the counter-
clockwise direction to remove.
Louver fixture
Horizontal air flow louvers
Air flow louver
Flathead screwdriver
Removing the
louver fixture
(Left side)
Fig. 12-1-7
4) After pushing in the right and left connector
joints, remove the vertical air flow louvres.
Remove the centre joint and bend the louver
downward.
Remove the right side joint first, and then,
remove the left side joint
Left side joint
Centre
joint
Fig. 12-1-8
Removing the
louver fixture
(Right side)
Right side joint

Hide quick links: