Toshiba RAS-M16PKVP-E Service Manual page 43

Air-conditioner split type
Hide thumbs Also See for RAS-M16PKVP-E:
Table of Contents

Advertisement

Outdoor Unit : RAS-5M34UAV-E
<Heating>
Temperature
-
No. of
condition
operating
units
Indoor
Outdoor
1 unit
2 units
3 units
20 / —
7 / 6
NOTES :
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor thermometer)
2. Connecting piping condition : 5 meters × 5 units (5m/each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
E
P (MPa)
07
2.1 to 2.3
10
2.7 to 2.9
13
3.2 to 3.4
16
3.6 to 3.9
18
3.6 to 3.9
16
07
2.8 to 3.0
16
10
2.9 to 3.1
16
13
3.0 to 3.2
16
16
3.1 to 3.3
18
07
2.9 to 3.1
18
10
2.9 to 3.1
18
13
3.1 to 3.3
18
16
3.1 to 3.3
18
18
3.1 to 3.3
07
07
07
2.3 to 2.5
10
07
07
2.3 to 2.5
13
07
07
2.3 to 2.5
16
07
07
2.3 to 2.5
18
07
07
2.3 to 2.5
10
10
07
2.3 to 2.5
13
10
07
2.3 to 2.5
16
10
07
2.3 to 2.5
18
10
07
2.5 to 2.7
13
13
07
2.5 to 2.7
16
13
07
2.5 to 2.7
18
13
07
2.5 to 2.7
16
16
07
2.5 to 2.7
18
16
07
2.5 to 2.7
18
18
07
2.5 to 2.7
10
10
10
2.3 to 2.5
13
10
10
2.3 to 2.5
16
10
10
2.5 to 2.7
18
10
10
2.5 to 2.7
13
13
10
2.5 to 2.7
16
13
10
2.5 to 2.7
18
13
10
2.5 to 2.7
16
16
10
2.5 to 2.7
18
16
10
2.5 to 2.7
18
18
10
2.5 to 2.7
13
13
13
2.5 to 2.7
16
13
13
2.5 to 2.7
18
13
13
2.5 to 2.7
16
16
13
2.5 to 2.7
18
16
13
2.5 to 2.7
18
18
13
2.5 to 2.7
– 43 –
Heat exchanger
pipe temperature
Indoor
fan
T1 (°C)
T2 (°C)
36 to 38
3 to 5
High
44 to 46
2 to 4
High
52 to 54
2 to 4
High
53 to 55
2 to 4
High
53 to 55
2 to 4
High
45 to 47
0 to 2
High
46 to 48
0 to 2
High
47 to 49
–1 to 1
High
48 to 50
–1 to 1
High
46 to 48
0 to 2
High
46 to 48
0 to 2
High
48 to 50
–1 to 1
High
48 to 50
–1 to 1
High
48 to 50
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
Compressor
Outdoor
revolution
fan
(rps)
MED
27
MED
38
MED
46
MED
50
MED
53
MED
48
MED
49
MED
52
MED
53
MED
49
MED
50
MED
53
MED
53
MED
53
MED
59
MED
59
MED
59
MED
59
MED
59
MED
59
MED
59
MED
59
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
59
MED
59
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents