LevelOne Infinity IES-0880 User Manual page 119

8 ge managed switch -20 to 60c, din-rail
Table of Contents

Advertisement

rw read-write access mode
4. Example:
The following example adds a user (myuser) using snmp v3 with read-only access mode
and without authentication:
switch_a(config)#snmp-server v3-user myuser ro noauth
switch_a(config)#
SNMPv3 Auth-MD5, SNMPv3 Auth-SHA:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Add a user using snmp v3 with read-only or read-write access mode and with MD5 or SHA
authentication. Use the no form of the command to delete this user.
3. Command Syntax:
(no) snmp-server v3-user USERNAME (ro|rw) auth (md5|sha) AUTH_PASSWORD
USERNAME Specify a user name.
ro read-only access mode
rw read-write access mode
md5 authentication method
sha authentication method
AUTH_PASSWORD authentication password
4. Example:
The following example adds a user (myuser) using snmp v3 with read-write access mode
and MD5 authentication (mypassword):
switch_a(config)#snmp-server v3-user myuser rw auth md5 mypassword
switch_a(config)#
SNMPv3 Priv Auth-MD5, SNMPv3 Priv Auth-SHA:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Add a user using snmp v3 with read-only or read-write access mode, MD5 or SHA
authentication, and privacy. Use the no form of the command to delete this user.
IES-0880 User Manual
Page 119

Advertisement

Table of Contents
loading

Table of Contents