The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use snmp-server trap-type enable coldStart command to enable cold start trap for
SNMP.
Use the no snmp-server trap-type enable coldStart command to disable cold start trap
for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable coldStart
4. Example:
The following example enables cold start trap for SNMP:
switch_a(config)#snmp-server trap-type enable coldStart
switch_a(config)#
Warm Start Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use snmp-server trap-type enable warmStart command to enable warm start trap for
SNMP.
Use the no snmp-server trap-type enable warmStart command to disable warm start
trap for SNMP.
3. Command Syntax:
(no) snmp-server trap-type enable warmStart
4. Example:
The following example enables warm start trap for SNMP:
switch_a(config)#snmp-server trap-type enable warmStart
switch_a(config)#
Link Down Trap:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#