LevelOne Infinity IES-0880 User Manual
LevelOne Infinity IES-0880 User Manual

LevelOne Infinity IES-0880 User Manual

8 ge managed switch -20 to 60c, din-rail

Advertisement

Quick Links

IES-0880
8 GE Managed Switch -20 to 60C, DIN-rail

User Manual

v1.00 - 1206

Advertisement

Table of Contents
loading

Summary of Contents for LevelOne Infinity IES-0880

  • Page 1: User Manual

    IES-0880 8 GE Managed Switch -20 to 60C, DIN-rail User Manual v1.00 - 1206...
  • Page 2 To get the most out of this manual, you should have an understanding of Ethernet networking concepts. In this manual, you will find:  Features on the Hardened Web-Smart PoE Ethernet Switch  Illustrative LED functions  Installation instructions  Management Configuration  Specifications IES-0880 User Manual Page 2...
  • Page 3: Table Of Contents

    OGGING ON TO THE SWITCH ....................23 NDERSTANDING THE ROWSER NTERFACE ................................25 YSTEM ................................... 32 ................................. 35 WITCHING ................................38 RUNKING STP / R ................................. 39 VLAN ................................. 45 S ..................................49 SNMP ................................51 IES-0880 User Manual Page 3...
  • Page 4 ................................89 RUNKING STP / R ................................. 90 VLAN ................................103 S .................................. 109 SNMP ................................112 802.1 ................................121 ............................126 THER ROTOCOLS SPECIFICATIONS ......................137 APPENDIX A ........................138 APPENDIX B ........................139 IES-0880 User Manual Page 4...
  • Page 5: Overview

    Overview LevelOne IES-0880 Industry Ethernet Switch provides 8 ports of Gigabit Ethernet to enable high speed network at mission-critical environment. This device is designed to be mounted on an industry standard DIN-rail, plus the clearly visible status LEDs provide simple monitoring of port link activity.
  • Page 6: Features

     -20℃ to 60℃ (-4℉ to 140℉) operating temperature range. UL508 Industrial Control Equipment certified Maximum Surrounding Air Temperature @ 60℃ (140℉).  For use in Pollution Degree 2 Environment.  Supports DIN-Rail and Panel Mounting installation. IES-0880 User Manual Page 6...
  • Page 7: Management

     Telnet remote access  SNMP agent: o MIB-2 (RFC1213) o Bridge MIB (RFC1493) o RMON MIB (RFC2819) statistics, history, alarm and events o VLAN MIB (IEEE802.1Q/RFC2674) o Private MIB  Web browser  TFTP software-upgrade capability IES-0880 User Manual Page 7...
  • Page 8: Package Contents

    When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller.  IES-0880 Hardened Managed Gigabit Ethernet Switch  Quick Installation Guide ...
  • Page 9: Front Panel Display

    ALA (Alarm) Redundancy Power is activated 10/100/1000Base-TX & 1000Base-SX / LX / BX Steady Network connection established LNK/ACT Flashing Transmitting or Receiving data Amber Connection at 1000Mbps Speed Green Connection at 100Mbps Connection at 10Mbps IES-0880 User Manual Page 9...
  • Page 10: Power Input

    2. The relay contact closes if Power3 is failed but Power1 and Power2 are both on 12VDC DC Jack Redundant DC Terminal Block There are two pairs of power inputs for use with redundant power sources. You only need to have one power input connected to run the switch. IES-0880 User Manual Page 10...
  • Page 11: Alarms For Power Failure

    Special Note The relay output is normal open position when there is no power to the switch. Please do not connect any power source to this terminal to prevent shorting your power supply. IES-0880 User Manual Page 11...
  • Page 12: Din Rain Mount

     Installation: Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place.  Removal: Pull out the lower edge and then remove the switch from the DIN rail. IES-0880 User Manual Page 12...
  • Page 13: Wiring Diagram

    Wiring Diagram Field Wiring Terminal Markings: Use Copper Conductors Only, 60/75℃, wire range 12-24 AWG, torque value 7 lb-in. IES-0880 User Manual Page 13...
  • Page 14: 10/100Base-Tx Connector

    Input Receive Data + Output Transmit Data - Input Receive Data - Input Receive Data + Output Transmit Data + Positive (VCC+) Positive (VCC+) Input Receive Data - Output Transmit Data - Negative (VCC-) Negative (VCC-) IES-0880 User Manual Page 14...
  • Page 15: Connecting To Your Network

    Step 4: Connect one end of the cable to the switch and the other end to a desired device. Step 5: Once the connections between two end devices are made successfully, turn on the power and the switch is operational. IES-0880 User Manual Page 15...
  • Page 16: Switch Management

    (workstation or personal computer) and the system. It also contains information about port connection options. Default Setting Console 115,200bps 8 data bits No parity 1 stop bit Web Interface IP address: 192.168.1.10 User Name: admin Password: [Blank] IES-0880 User Manual Page 16...
  • Page 17: Console (Cli)

    The switch echoes characters that it receives as input on the modem port to the current administration console session. The console appears to be directly connected to the external modem. IES-0880 User Manual Page 17...
  • Page 18: Web Management

    The management architecture of the switch adheres to the IEEE open standard. This compliance assures customers that the switch is compatible with, and will interoperate with other solutions that adhere to the same open standard. IES-0880 User Manual Page 18...
  • Page 19: Snmp & Rmon Management

    - Setting MIB variables according to the SNMP SET frame message. - Generating an SNMP TRAP frame message to the Network Management Station if the threshold of a certain MIB counter is reached or if other trap conditions (such as the following) are met: IES-0880 User Manual Page 19...
  • Page 20: Rmon Mib (Rfc 2819) And Bridge Mib (Rfc 1493)

    - RMON Event Group allows a network administrator to define actions based on alarms. SNMP Traps are generated when RMON Alarms are triggered. The action taken in the Network Management Station depends on the specific network management application. IES-0880 User Manual Page 20...
  • Page 21: Bridge Groups Supported

    - The dot1dTp Group status. This group is applicable to transparent operation only and SRT bridges. - The dot1dStatic Group -address filtering status. This group is applicable to any type of bridge which performs destination- address filtering. IES-0880 User Manual Page 21...
  • Page 22: Web-Based Management

    In your web browser, specify the IP address of the switch. Default IP address is 192.168.1.10. LOGIN Enter the factory default login ID: root. PASSWORD Enter the factory default password (no password). Or enter a user-defined password if you followed the instructions later and changed the factory default password. IES-0880 User Manual Page 22...
  • Page 23: Understanding The Browser Interface

    Bridging, Static MAC Entry, Port Mirroring TRUNKING Port Trunking STP / RING Global Configuration, RSTP Port Setting, MSTP Properties, MSTP Instance Setting, MSTP Port Setting, Ring Setting VLAN VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based VLAN IES-0880 User Manual Page 23...
  • Page 24: Other Protocols

    Global Configuration, 802.1p Priority, DSCP SNMP SNMP General Setting, SNMP v1/v2c, SNMP v3 802.1X Radius Configuration, Port Authentication OTHER PROTOCOLS GVRP, IGMP Snooping, NTP IES-0880 User Manual Page 24...
  • Page 25: System

    Updating setting button to update your settings. 3. Password: Password . Type a password. 4. Retype Password: Retype Password . Type the same password in Password again to verify it. 5. Updating setting: Updating setting button to update your settings. IES-0880 User Manual Page 25...
  • Page 26 DNS Server drop-down list to disable or enable DNS Server Setting for the switch. Click the text box and type a new address to change the DNS Server. (Need to choose Enable DNS Server drop-down menu.) 8. Submit: C Submit button when you finished DNS Server. IES-0880 User Manual Page 26...
  • Page 27: Save Configuration

    Auto save drop-down list to disable or enable Auto save for the switch. 6. Auto save interval (5~65536 sec): C Auto save interval decimal number between 5 and 65536. 7. Submit: C Submit button when you finished Auto save configuration. IES-0880 User Manual Page 27...
  • Page 28: Firmware Upgrade

    Reboot the switch after completing the upgrade process. Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functions during this period of time. IES-0880 User Manual Page 28...
  • Page 29 Firmware has been upgraded successfully to the switch. Reboot the switch after completing the upgrade process. IES-0880 User Manual Page 29...
  • Page 30 Reboot Reboot: Reboot button to restart the switch. IES-0880 User Manual Page 30...
  • Page 31 Logout Logout: Logout button to logout of the switch. IES-0880 User Manual Page 31...
  • Page 32: Port

    3. Flow control: C Flow control drop-down menu to choose Disable or Enable Flow control drop-down list to disable or enable Flow control for the port. 4. Submit: C Submit button when you finished configurations. IES-0880 User Manual Page 32...
  • Page 33: Port Status

    Rate Values: 64kbps, 128kbps, 192kbps, , 1792kbps. 2Mbps, 3Mbps, 4Mbps, , 100Mbps. 104Mbps, 112Mbps, 120Mbps, , 1000Mbps. <Note>: M = 1024k. 3. Update setting: C Update setting button when you finished these Rate Control settings. IES-0880 User Manual Page 33...
  • Page 34: Rmon Statistics

    RMON Statistics Click Port 1 ~ Port 8 to view corresponding RMON Statistics. Per port vlan activities Click Port 1 ~ Port 8 to view corresponding vlan activities. IES-0880 User Manual Page 34...
  • Page 35: Switching

    DLF (Destination Lookup Failure). 4. Storm-control enabled type: Choose Broadcast and/or DLF-Multicast from Storm- control enabled type for the port. 5. Update Setting: C Update Setting button when you finished Threshold level and Storm-control enabled type settings. IES-0880 User Manual Page 35...
  • Page 36 3. Delete MAC address: C Delete MAC address drop-down menu and choose a MAC address Delete MAC address drop-down list to be discarded from the VLAN. 4. Submit: C Submit button when you finished Static-MAC-Entry Discard settings. IES-0880 User Manual Page 36...
  • Page 37: Port Mirroring

    Mirror To drop-down list. 3. Mirror Mode: C Mirror Mode drop-down menu to Choose Tx/Rx , Tx , or Rx from Mirror Mode drop-down list. 4. Submit: C Submit button when you finished Port Mirroring settings. IES-0880 User Manual Page 37...
  • Page 38: Trunking

    1. Trunk 1 ~ 4: Trunk 1: Click Port 1 ~ Port 8 to assign ports to Trunk 1 ~ 4. (Maximum 4 ports per Trunk.) 2. Submit: C Submit button when you finished Port Trunking settings. IES-0880 User Manual Page 38...
  • Page 39: Stp / Ring

    4 and 30. 6. STP Version: C STP Version drop-down menu to choose MSTP , RSTP , or STP compatible from STP Version drop-down list. 7. Update setting: C Update setting button when you finished Global Configuration. IES-0880 User Manual Page 39...
  • Page 40 Edge Port drop-down menu to Choose Enable , Disable , or Auto from Edge Port drop-down list to set Enable, Disable, or Auto Edge Port for the port. 7. Update setting: C Update setting button when you finished RSTP Port Setting. IES-0880 User Manual Page 40...
  • Page 41: Mstp Properties

    BPDU prevents the messages from looping indefinetely in the network. When a bridge receives a MST BPDU that has exceeded the allowed max-hops, it discards the BPDU. 5. Update setting: C Update setting button when you finished MSTP Properties setting. IES-0880 User Manual Page 41...
  • Page 42 MST instance to the value specified. The lower the priority of the bridge, the better the chances are the bridge becoming a root bridge or a designated bridge for the LAN. 2. Update setting: C Update setting button when you finished VLAN Instance Configuration. IES-0880 User Manual Page 42...
  • Page 43 0-240. The priority values can only be set in increments of 16. 3. Admin. Path Cost: C Admin. Path Cost to set the cost of a path associated with an interface. 4. Update setting: C Update setting button when you finished MSTP Port Setting. IES-0880 User Manual Page 43...
  • Page 44 1 drop-down list. 2. Ring port 2: C Ring port 2 drop-down menu to choose Ring port 2 from Ring port 2 drop-down list. 3. Update setting: C Update setting button when you finished Set ring port. IES-0880 User Manual Page 44...
  • Page 45: Vlan

    1. VLAN Mode Setting: C VLAN Mode Setting drop-down menu to choose Tag- based VLAN or Port-based VLAN from VLAN Mode Setting drop-down list. 2. Update Setting: C Update Setting button when you finished VLAN Mode Setting. IES-0880 User Manual Page 45...
  • Page 46: Q Vlan Setting

    2. Tag or Untag: C Tag or Untag drop-down menu to Choose Tag or Untag from Tag or Untag drop-down list for a Hybrid port. 3. Submit: C Submit button when you finished VLAN setting. IES-0880 User Manual Page 46...
  • Page 47: Vlan Port Setting

    Mode for the port. And the port will be Tag or Untag port if you choose Hybrid Mode for the port. 3. PVID: PVID textbox and specify a new PVID number for the port. 4. Update Setting: C Update Setting button when you finished VLAN Port Setting. IES-0880 User Manual Page 47...
  • Page 48 Port 1 ~ Port 8 all to be added to the VLAN. 3. Delete all: C delete all button to choose Port 1 ~ Port 8 all to be deleted from the VLAN. 4. Submit: C Submit button when you finished Port Based VLAN setting. IES-0880 User Manual Page 48...
  • Page 49: Qos

    4. Weighted Round Robin: Weight(1~55) textbox and specify a new number from 1 ~ 55 for Queue 0 ~ 3. 5. Submit: C Submit button when you finished Global Configuration. IES-0880 User Manual Page 49...
  • Page 50 Submit button when you finished 802.1p priority. DSCP 1. Priority: C Priority drop-down menu from Priority drop-down list to choose 0 ~ 3 for DSCP Priority 0 ~ 63. 2. Submit: C Submit button when you finished DSCP. IES-0880 User Manual Page 50...
  • Page 51: Snmp

    Authentication Failure Trap drop-down menu from Authentication Failure Trap drop-down list to choose Enable or Disable to enable or disable authentication failure trap. 12. Topology Change Trap: C Topology Change Trap drop-down menu from Topology IES-0880 User Manual Page 51...
  • Page 52 Get Community Name textbox and specify a get community name. 2. Set Community Name: Set Community Name textbox and specify a set community name. 3. Update Setting: C Update Setting button when you finished SNMP V1/V2c Setting. IES-0880 User Manual Page 52...
  • Page 53  Read Only: Add a user using SNMP v3 with read-only access mode.  Read/Write: Add an user using SNMP v3 with read-write access mode 5. Sumit: C Sumit button when you finished SNMP V3 Setting. IES-0880 User Manual Page 53...
  • Page 54 2. Select User Name: C Select User Name drop-down menu from Select User Name drop-down list to choose the user to be deleted from using SNMP v3. 3. Sumit: C Sumit button when you finished user deletion. IES-0880 User Manual Page 54...
  • Page 55: Radius Configuration

    Switch and radius server. This key must match the encryption used on the radius daemon. All leading spaces are ignored, but spaces within and at the end of the key are used. If spaces are used in the IES-0880 User Manual Page 55...
  • Page 56 Select Radius Server IP drop-down menu from Select Radius Server IP drop-down list to choose the IP address of the remote radius server host to be deleted. 3. Sumit: C Sumit button when you finished radius server deletion. IES-0880 User Manual Page 56...
  • Page 57 5. Reauthentication Period <1-4294967295>: Reauthentication Period textbox and specify the seconds between reauthorization attempts. The default time is 3600 seconds. 6. Update Setting: C Update Setting button when you finished port-based authentication setting. IES-0880 User Manual Page 57...
  • Page 58: Other Protocols

    Configuring an IEEE802.1Q trunk port in registration mode allows dynamic creation (if dynamic VLAN creation is enabled), registration, and deregistration of VLANs on the trunk port. 4. Update Setting: Click Update Setting button when you finished Per port setting. IES-0880 User Manual Page 58...
  • Page 59: Igmp Snooping

    The switch does not send the remaining IGMP reports for the group to the multicast routers. This feature prevents duplicate reports from being sent to the multicast devices. Update Setting: C Update Setting button when you finished IGMP Snooping. IES-0880 User Manual Page 59...
  • Page 60 Enter the Daylight-Saving time zone using the following example: EDT - East Daylight Saving Time Zone. CDT - Central Daylight-Saving Time Zone. MDT - Mountain Daylight-Saving Time Zone. PDT - Pacific Daylight-Saving Time Zone. IES-0880 User Manual Page 60...
  • Page 61 6. Update Setting: Click "Update Setting" button when you finished Daylight Saving Setting. <Note> T , Hour , Minute , s would not accept the alphabetic characters (Like Jan, Feb, sun, mon). They only accept the two digit numbers (0 throught 9). IES-0880 User Manual Page 61...
  • Page 62: Console Management

    When using the management method, configure the terminal-emulation program to use the following parameters (you can change these settings after login): [Default parameters] 115,200bps 8 data bits No parity 1 stop bit IES-0880 User Manual Page 62...
  • Page 63: Exec Mode (View Mode)

    The CLI contains a text-based help facility. Access this help by typing in the full or partial command string then or parameters along with a short description. At the switch_a> prompt just press <?> to list the above basic commands. switch_a>? IES-0880 User Manual Page 63...
  • Page 64 At the switch_a> prompt just type in the full or partial command string then typing a to display the command keywords or parameters along with a short description. switch_a>show ? Login timed out IES-0880 User Manual Page 64...
  • Page 65 Logon back to Exec Mode (View Mode) At the switch_a login: Mode (or View Mode). switch_a login: root Exit from Exec Mode (View Mode) At the switch_a> to exit from Exec Mode (or View Mode). switch_a>exit IES-0880 User Manual Page 65...
  • Page 66: Privileged Exec Mode (Enable Mode)

    Exec Mode (or Enable Mode). And the switch_a# prompt will show on the screen. switch_a>enable Commands Privileged Exec Mode (or Enable Mode) allows users to run commands as following. At the switch_a# prompt just press <?> to list the commands. switch_a#? IES-0880 User Manual Page 66...
  • Page 67 At the switch_a# prompt just type in the full or partial command string then typing a to display the command keywords or parameters along with a short description. switch_a#show ? Login timed out IES-0880 User Manual Page 67...
  • Page 68 Logon back to Exec Mode (View Mode) At the switch_a login: Mode (or View Mode). switch_a login: root Exit from Privileged Exec Mode (or Enable Mode) At the switch_a# to exit from Privileged Exec Mode (or Enable Mode). switch_a#exit IES-0880 User Manual Page 68...
  • Page 69: Configure Mode (Configure Terminal Mode)

    Configure Mode (or Configure Terminal Mode). And the switch_a(config)# prompt will show on the screen. switch_a#configure terminal Commands Configure Mode (or Configure Terminal Mode) serves as a gateway into the modes as following. At the switch_a(config)# prompt just press <?> to list the commands. switch_a(config)#? IES-0880 User Manual Page 69...
  • Page 70 (60 seconds) to indicate authentication attempt timed out. And the switch_a login: prompt will show on the screen. Logon back to Exec Mode (View Mode) At the switch_a login: Mode (or View Mode). switch_a login: root IES-0880 User Manual Page 70...
  • Page 71 Exit from Configure Mode (or Configure Terminal Mode) At the switch_a(config)# Configure Mode (or Configure Terminal Mode). switch_a(config)#exit IES-0880 User Manual Page 71...
  • Page 72: System

    Use enable password command to modify or create a password to be used when entering the Enable mode. 3. Command Syntax: enable password PASSWORD PASSWORD specifies the new password of the system. 4. Example: The following example sets the new password mypasswd to switch: switch_a(config)#enable password mypasswd switch_a(config)# IES-0880 User Manual Page 72...
  • Page 73 Use the no ip default-gateway command to remove the IP address of the default gateway. 3. Command Syntax: ip default-gateway IP-ADDRESS no ip default-gateway IP-ADDRESS A.B.C.D specifies the IP address of the default gateway. 4. Example: IES-0880 User Manual Page 73...
  • Page 74 IP-ADDRESS specifies the IP address of tftp server. WORD specifies the file name to be loaded to switch. 4. Example: The following example specifies upgrading firmware (file name: flash.tgz) from tftp server (IP address: 192.168.1.100) to switch: switch_a#install image 192.168.1.100 flash.tgz IES-0880 User Manual Page 74...
  • Page 75 3. Command Syntax: copy running-config startup-config 4. Example: The following example specifies writing configurations to the file to be used at startup to switch: switch_a#copy running-config startup-config switch_a# Restore Default: 1. Command Mode: Privileged Exec mode IES-0880 User Manual Page 75...
  • Page 76 Auto Save Interval (5~65536 sec): 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on the screen. switch_a(config)# 2. Usage: IES-0880 User Manual Page 76...
  • Page 77 (IP address: 192.168.1.100) to switch: switch_a#install image 192.168.1.100 flash.tgz switch_a# Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functions during this period of time. IES-0880 User Manual Page 77...
  • Page 78 Logon to Privileged Exec Mode (Enable Mode). The switch_a# prompt will show on the screen. switch_a# 2. Usage: Use reload command to restart switch. 3. Command Syntax: reload 4. Example: The following example specifies restarting switch: IES-0880 User Manual Page 78...
  • Page 79 Use logout command to exit from the Exec mode or Privileged Exec mode. 3. Command Syntax: logout 4. Example: The following example specifies to exit from the Exec mode or Privileged Exec mode. switch_a>logout switch_a login: IES-0880 User Manual Page 79...
  • Page 80: Port

    The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if )# 2. Usage: Use duplex command to specify the duplex mode to be used for each interface. Use the no duplex to disable this function. 3. Command Syntax: (no) duplex MODE IES-0880 User Manual Page 80...
  • Page 81 Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode). The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a# 2. Usage: Use the show interface command to display interface configuration and status. IES-0880 User Manual Page 81...
  • Page 82 )# RMON Statistics 1. Command Mode: Exec mode or Privileged Exec mode Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode). The switch_a> or switch_a# prompt will show on the screen. IES-0880 User Manual Page 82...
  • Page 83: Per Port Vlan Activities

    Use show vlan command to display information about a particular VLAN by specifying the VLAN ID. 3. Command Syntax: show vlan <2-4094> <2-4094> VLAN ID. 4. Example: The following is an output of show vlan command displaying information about VLAN 2: switch_a>show vlan 2 IES-0880 User Manual Page 83...
  • Page 84: Switching

    The storm control action occurs when traffic utilization reaches this level. 3. Command Syntax: storm-control level LEVEL LEVEL <0-100> specifies the percentage of the threshold; percentage of the maximum speed (pps) of the interface. IES-0880 User Manual Page 84...
  • Page 85 Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. fe1 means port 1. The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if )# 2. Usage: Use storm-control multicast enable command to enable multicast traffic. IES-0880 User Manual Page 85...
  • Page 86 The following example shows setting storm-control dlf enable to the interface fe1 (port switch_a(config)#interface fe1 switch_a(config-if )#storm-control dlf enable switch_a(config-if )# Static MAC Entry Static-MAC-Entry Forward: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on the screen. IES-0880 User Manual Page 86...
  • Page 87 VLANID The VID of the VLAN on the bridge <1-4094>. 4. Example: The following example configures a bridge GROUP (1) to discard matching frames (MAC address 2222.2222.2222) in vlan VLANID (1): switch_a(config)#bridge 1 address 2222.2222.2222 discard vlan 1 switch_a(config)# IES-0880 User Manual Page 87...
  • Page 88 Specifies mirroring of transmitted traffic. 4. Example: The following example enables port mirroring by the destination port fe1 (port 1) on the specified source port fe2 (port 2): switch_a(config)#interface fe1 switch_a(config-if )#mirror interface fe2 direction both switch_a(config-if )# IES-0880 User Manual Page 88...
  • Page 89: Trunking

    Maximum 4 ports in static-channel-group 1 and static-channel-group 2. Maximum 2 ports in static-channel-group 3 4. Example: The following example adding the interface fe1 (port 1) to static-channel-group 1: switch_a(config)#interface fe1 switch_a(config-if )#static-channel-group 1 switch_a(config-if )# IES-0880 User Manual Page 89...
  • Page 90: Stp / Ring

    Use the no form of the command to disable the Multiple Spanning Tree protocol on a bridge. 3. Command Syntax: bridge GROUP multiple-spanning-tree enable no bridge GROUP multiple-spanning-tree enable BRIDGE-FORWARD GROUP <1-1> Bridge group name used for bridging. IES-0880 User Manual Page 90...
  • Page 91 Use the no form of the command to disable the Spanning Tree protocol on a bridge. 7. Command Syntax: bridge GROUP spanning-tree enable no bridge GROUP spanning-tree enable BRIDGE-FORWARD GROUP <1-1> Bridge group name used for bridging. IES-0880 User Manual Page 91...
  • Page 92 Use this command to set the hello-time, the time in seconds after which (if this bridge is the root bridge) all the bridges in a bridged LAN exchange Bridge Protocol Data Units (BPDUs). 3. Command Syntax: bridge GROUP hello-time HELLOTIME no bridge GROUP hello-time IES-0880 User Manual Page 92...
  • Page 93 Use this command to set the time (in seconds) after which (if this bridge is the root bridge) each port changes states to learning and forwarding. Use the no parameter with this command to restore the default value. 3. Command Syntax: bridge GROUP forward-time FORWARD_DELAY no bridge GROUP forward-time IES-0880 User Manual Page 93...
  • Page 94 Admin. Path Cost: 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. fe1 means port 1. The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if )# IES-0880 User Manual Page 94...
  • Page 95 LINKTYPE The link type to be assigned to the port. point-to-point Enable rapid transition. shared Disable rapid transition. 4. Example: The following example sets the link-type LINKTYPE (point-to-point) of the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if )#spanning-tree link-type point-to-point switch_a(config-if )# IES-0880 User Manual Page 95...
  • Page 96 Use the no spanning-tree edgeport command to set a port to its default state (not an edge-port) and to disable rapid transitions. 3. Command Syntax: (no) spanning-tree edgeport 4. Example: The following example enables the spanning-tree edgeport of the interface fe1 (port 1): switch_a(config)#interface fe1 IES-0880 User Manual Page 96...
  • Page 97 Then logon to MST Configuration mode. The switch_a(config-mst)# prompt will show on the screen. switch_a(config)#spanning-tree mst configuration switch_a(config-mst)# 2. Usage: Use this command to specify the number for configuration information. The default value of revision number is 0. IES-0880 User Manual Page 97...
  • Page 98 MSTP Instance Setting Bridge Instance VLAN: 1. Command Mode: MST Configuration mode Logon to Configure Mode (Configure Terminal Mode). Then logon to MST Configuration mode. The switch_a(config-mst)# prompt will show on the screen. switch_a(config)#spanning-tree mst configuration IES-0880 User Manual Page 98...
  • Page 99 GROUP <1-1> Specify the bridge-group ID. INSTANCE_ID Specify the instance ID. BRIDGE_PRIORITY <0-61440> Specify the bridge priority. 4. Example: The following example sets the bridge priority (0) for an MST instance (3) in bridge GROUP (1): IES-0880 User Manual Page 99...
  • Page 100 Use this command to set the port priority for a bridge group. The Multiple Spanning Tree Protocol uses port priority as a tiebreaker to determine which port should forward frames for a particular instance on a LAN, or which port should be the root port for an instance. A IES-0880 User Manual Page 100...
  • Page 101 4. Example: The following example sets the path cost (1000) for Multiple Spanning Tree instance (3) to a port (fe1) in bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if )#bridge-group 1 instance 3 path-cost 1000 switch_a(config-if )# IES-0880 User Manual Page 101...
  • Page 102 RING_PORT_1 Specify the Ring port 1. RING_PORT_2 Specify the Ring port 2. 4. Example: The following example sets the fe1 and fe2 as Ring port 1 and Ring port 2: switch_a(config)#ring set-port fe1 fe2 switch_a(config)# IES-0880 User Manual Page 102...
  • Page 103: Vlan

    VLANID The VID of the VLAN that will be enabled or disabled on the bridge <2-4094>. GROUP <1-1> The ID of the bridge-group on which the VLAN will be affected. VLAN_NAME The ASCII name of the VLAN. Maximum length: 16 characters. enable Sets VLAN into an enable state. IES-0880 User Manual Page 103...
  • Page 104 Switchport mode hybrid: 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. fe1 means port 1. The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if )# IES-0880 User Manual Page 104...
  • Page 105 (default). 3. Command Syntax: switchport mode trunk no switchport trunk 4. Example: The following example sets the switchport mode trunk of the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if )#switchport mode trunk switch_a(config-if )# IES-0880 User Manual Page 105...
  • Page 106 2 egress-tagged enable switch_a(config-if)# Switchport trunk allowed vlan: 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. fe1 means port 1. IES-0880 User Manual Page 106...
  • Page 107 Switchport portbase add/remove vlan: 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. fe1 means port 1. The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if )# IES-0880 User Manual Page 107...
  • Page 108 VLANID The ID of the VLAN will be added to or removed from the Layer-2 interface. 4. Example: The following example specifies to add the interface fe1 (port 1) to VLANID (2): switch_a(config)#interface fe1 switch_a(config-if )#switchport portbase add vlan 2 switch_a(config-if )# IES-0880 User Manual Page 108...
  • Page 109: Qos

    3. Command Syntax: (no) mls qos trust cos/dscp cos Class of Service. dscp Differentiated Service Code Point. 4. Example: The following example turns on QoS trust CoS on the switch: switch_a(config)#mls qos trust cos switch_a(config)# IES-0880 User Manual Page 109...
  • Page 110 WRR_WTS Weighted Round Robin (WRR) weights for the 4 queues (4 values separated by spaces). Range is 1-55. 4. Example: The following example specifies the bandwidth ratios of the transmit queues on the switch: switch_a(config)#wrr-queue bandwidth 1 2 4 8 switch_a(config)# 802.1p Priority 1. Command Mode: Configure mode IES-0880 User Manual Page 110...
  • Page 111 QUEUE_ID Queue ID. Range is 0-3. 4. Example: The following example shows mapping DSCP values 0 to 3 to queue 1 on the switch: switch_a(config)#mls qos map dscp-queue 0 1 2 3 to 1 switch_a(config)# IES-0880 User Manual Page 111...
  • Page 112: Snmp

    Use snmp-server description command to specify and no snmp-server description command to remove description for SNMP. 3. Command Syntax: snmp-server description DESCRIPTION no snmp-server description DESCRIPTION The description for SNMP. 4. Example: The following example specifies description (description) for SNMP: switch_a(config)#snmp-server description description switch_a(config)# IES-0880 User Manual Page 112...
  • Page 113 3. Command Syntax: snmp-server contact CONTACT no snmp-server contact CONTACT The contact for SNMP. 4. Example: The following example specifies contact (contact) for SNMP: switch_a(config)#snmp-server contact contact switch_a(config)# Trap Community Name: 1. Command Mode: Configure mode IES-0880 User Manual Page 113...
  • Page 114 IP-ADDRESS The trap host IP address for SNMP. A.B.C.D specifies the IP address. 4. Example: The following example specifies trap host 1 IP address (192.168.1.20) for SNMP: switch_a(config)#snmp-server trap-ipaddress 1 192.168.1.20 switch_a(config)# Cold Start Trap: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). IES-0880 User Manual Page 114...
  • Page 115 The following example enables warm start trap for SNMP: switch_a(config)#snmp-server trap-type enable warmStart switch_a(config)# Link Down Trap: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on the screen. switch_a(config)# IES-0880 User Manual Page 115...
  • Page 116 Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on the screen. switch_a(config)# 2. Usage: Use snmp-server trap-type enable authenticationFailure command to enable authentication failure trap for SNMP. Use the no snmp-server trap-type enable authenticationFailure command to disable IES-0880 User Manual Page 116...
  • Page 117 The switch_a(config)# prompt will show on the screen. switch_a(config)# 2. Usage: Use snmp-server community get command to specify and no snmp-server community get command to remove get community name for SNMP. 3. Command Syntax: snmp-server community get NAME IES-0880 User Manual Page 117...
  • Page 118 Add a user using snmp v3 with read-only or read-write access mode and without authentication. Use the no form of the command to delete this user. 3. Command Syntax: (no) snmp-server v3-user USERNAME (ro|rw) noauth USERNAME Specify a user name. ro read-only access mode IES-0880 User Manual Page 118...
  • Page 119 The switch_a(config)# prompt will show on the screen. switch_a(config)# 2. Usage: Add a user using snmp v3 with read-only or read-write access mode, MD5 or SHA authentication, and privacy. Use the no form of the command to delete this user. IES-0880 User Manual Page 119...
  • Page 120 PRIV_PASS_PHRASE encryption pass phrase 4. Example: The following example adds a user (myuser) using snmp v3 with read-write access mode, MD5 authentication (mypassword), and encryption pass phrase (mypassphrase): switch_a(config)#snmp-server v3-user myuser rw priv md5 mypassword des mypassphrase switch_a(config)# IES-0880 User Manual Page 120...
  • Page 121 0. 4. Example: The following example specifies the IP address (192.168.1.100) of the remote radius server host and assigns authentication and accounting destination port number (1812): switch_a(config)#radius-server host 192.168.1.100 auth-port 1812 IES-0880 User Manual Page 121...
  • Page 122 Enter a value in the range 1 to 1000. 4. Example: The following example specifies 20 seconds for the Switch to wait for a server host to reply before timing out: switch_a(config)#radius-server timeout 20 IES-0880 User Manual Page 122...
  • Page 123: Port Authentication

    Use no dot1x reauthetication command to disable reauthentication on a port. 3. Command Syntax: (no) dot1x reauthentication 4. Example: The following example specifies to enable reauthetication on the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if )#dot1x reauthentication IES-0880 User Manual Page 123...
  • Page 124 The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if )# 2. Usage: Use this command to set the interval between reauthorization attempts. Use no dot1x timeout re-authperiod command to delete the interval between reauthorization attempts. IES-0880 User Manual Page 124...
  • Page 125 SECS <1-4294967295> Specify the seconds between reauthorization attempts. The default time is 3600 seconds. 4. Example: The following example specifies to set the interval 25 seconds between reauthorization attempts: switch_a(config)#interface fe1 switch_a(config-if )#dot1x timeout re-authperiod 25 switch_a(config-if )# IES-0880 User Manual Page 125...
  • Page 126: Other Protocols

    VLAN creation for a specific bridge instance. 3. Command Syntax: set gvrp dynamic-vlan-creation enable bridge GROUP set gvrp dynamic-vlan-creation disable bridge GROUP GROUP Bridge-group ID used for bridging. 4. Example: IES-0880 User Manual Page 126...
  • Page 127 Use this command to set the GVRP applicant state to normal or active. 3. Command Syntax: set gvrp applicant state active/normal IFNAME active Active state normal Normal state IFNAME Name of the interface. 4. Example: IES-0880 User Manual Page 127...
  • Page 128 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on the screen. switch_a(config)# 2. Usage: Use ip igmp snooping querier command to enable IGMP querier operation on a subnet IES-0880 User Manual Page 128...
  • Page 129 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. vlan1.1 means vlan 1. The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if )# 2. Usage: IES-0880 User Manual Page 129...
  • Page 130 4. Example: The following example enables IGMP snooping fast-leave on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if )#ip igmp snooping fast-leave switch_a(config-if )# IGMP querier: Query-interval: 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). IES-0880 User Manual Page 130...
  • Page 131 To restore to the default value, use the no ip igmp query-max-response-time command. 3. Command Syntax: ip igmp query-max-response-time RESPONSETIME no ip igmp query-max-response-time RESPONSETIME <1-240> Maximum response time (in seconds) advertised in IGMP queries. Default: 10 seconds. IES-0880 User Manual Page 131...
  • Page 132 Report suppression: 1. Command Mode: Interface mode Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface mode. vlan1.1 means vlan 1. The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if )# IES-0880 User Manual Page 132...
  • Page 133 The following example enables NTP for the Switch: switch_a(config)#ntp enable switch_a(config)# NTP Server: 1. Command Mode: Configure mode Logon to Configure Mode (Configure Terminal Mode). The switch_a(config)# prompt will show on the screen. switch_a(config)# 2. Usage: IES-0880 User Manual Page 133...
  • Page 134 The switch_a(config)# prompt will show on the screen. switch_a(config)# 2. Usage: Use this command to to set time zone. 3. Command Syntax: clock timezone TIMEZONE TIMEZONE Specifies the time zone. (Please refer the Appendix B) 4. Example: IES-0880 User Manual Page 134...
  • Page 135 HOUR <0-23> Specifies from 0 to 23. MINUTE <0-59> Specifies from 0 to 59. OFFSET <1-1440> Specifies from 1 to 1440 minutes. clock summer-time TIMEZONE date DAY MONTH HOUR MINUTE DAY MONTH HOUR MINUTE OFFSET IES-0880 User Manual Page 135...
  • Page 136 The following example sets clock summer-time TIMEZONE (onehour) as daylight saving offset 60 minutes from 4 April AM0:00 to 31 October AM0:00: switch_a(config)#clock summer-time onehour date 4 4 0 0 31 10 0 0 60 switch_a(config)# IES-0880 User Manual Page 136...
  • Page 137: Specifications

    EN61000-4-2 (ESD Standard) EN61000-4-3 (Radiated RFI Standards) EN61000-4-4 (Burst Standards) EN61000-4-5 (Surge Standards) EN61000-4-6 (Induced RFI Standards) EN61000-4-8 (Magnetic Field Standards) IEC60068-2-6 Fc (Vibration Resistance) Environmental Test IEC60068-2-27 Ea (Shock) Compliance IEC60068-2-32 Ed (Free Fall) IES-0880 User Manual Page 137...
  • Page 138: Appendix A

    Appendix A DB9 DCE pin assignment Name RS232 Signal name Data Carrier detect Received data Transmit data Signal ground Data set Ready Clear to send IES-0880 User Manual Page 138...
  • Page 139: Appendix B

    EUT-3EUTDST Asia/Tbilisi EUT-4EUTDST Europe/Samara EUT-6EUTDST Asia/Almaty, Asia/Qyzylorda EUT-8EUTDST Asia/Ulaanbaatar Russian Federation RFT-2RFTDST Europe/Kaliningrad RFT-3RFTDST Europe/Moscow RFT-4RFTDST Asia/Yerevan, Asia/Baku, Asia/Oral, Asia/Ashkhabad RFT-5RFTDST Asia/Aqtobe, Asia/Aqtau, Asia/Bishkek, Asia/Yekaterinburg RFT-6RFTDST Asia/Omsk, Asia/Novosibirsk RFT-7RFTDST Asia/Hovd, Asia/Krasnoyarsk RFT-8RFTDST Asia/Irkutsk, Asia/Chungking, Asia/Ulan_Bator IES-0880 User Manual Page 139...
  • Page 140 America/St_Johns, Canada/Newfoundland NAST3NADT America/Godthab, America/Miquelon NAST9NADT Pacific/Pitcairn, America/Juneau, America/Yakutat, America/Anchorage, America/Nome, US/Alaska, SystemV/YST9YDT, SystemV/PST8 South America & Central America TTST4 America/Port_of_Spain SAT3 America/Argentina/Buenos_Aires, America/Argentina/Cordoba, America/Argentina/Tucuman, America/Argentina/La_Rioja, America/Argentina/San_Juan, America/Argentina/Jujuy, America/Argentina/Catamarca, America/Argentina/Mendoza, America/Argentina/Rio_Gallegos, America/Argentina/Ushuaia, America/Argentina/ComodRivadavia, America/Buenos_Aires, America/Cordoba, IES-0880 User Manual Page 140...
  • Page 141 NZST-12NZDT Antarctica/McMurdo, Pacific/Auckland, Antarctica/South_Pole, NZ CIST-12:45CIDT Pacific/Chatham, NZ-CHAT Africa SAST-2 Africa/Maseru, Africa/Johannesburg, Africa/Mbabane EST-2EDT Africa/Cairo, Egypt UAEST-4 Asia/Dubai IST-3IDT Asia/Baghdad JST-2JDT Asia/Amman SST-2SDT Asia/Damascus Universal Africa/Ouagadougou, Africa/Abidjan, Africa/Banjul, Africa/Accra, Africa/Conakry, Africa/Bissau, Africa/Monrovia, Africa/Bamako, Africa/Nouakchott, Africa/Casablanca, IES-0880 User Manual Page 141...
  • Page 142 UCT11 Pacific/Niue, Pacific/Pago_Pago, Pacific/Apia, Pacific/Midway, Etc/GMT+11, Pacific/Samoa, US/Samoa UCT-1 Africa/Algiers, Africa/Luanda, Africa/Porto-Novo, Africa/Douala, Africa/Bangui, Africa/Ndjamena, Africa/Kinshasa, Africa/Brazzaville, Africa/Malabo, Africa/Libreville, Africa/Windhoek, Africa/Niamey, Africa/Lagos, Etc/GMT-1 UCT-2 Africa/Gaborone, Africa/Bujumbura, Africa/Lubumbashi, Africa/Tripoli, Africa/Blantyre, Africa/Maputo, Africa/Kigali, Africa/Lusaka, Africa/Harare, Etc/GMT-2, Libya IES-0880 User Manual Page 142...
  • Page 143 Pacific/Tongatapu, Pacific/Funafuti, Pacific/Wake, Pacific/Efate, Pacific/Wallis, Etc/GMT-12, Kwajalein UCT-13 Etc/GMT-13 Asia/Tokyo, Japan Asia/Seoul, Asia/Pyongyang, ROK UCT-3:30 Asia/Tehran, Iran UCT-4:30 Asia/Kabul IST-2IDT Asia/Jerusalem, Asia/Gaza, Asia/Tel_Aviv, Israel CST6MEX America/Cancun, America/Merida, America/Monterrey, America/Mexico_City, America/Lima, Mexico/General CST6 America/Regina, America/Swift_Current, Canada/East-Saskatchewan, IES-0880 User Manual Page 143...
  • Page 144 America/Tijuana, America/Ensenada, Mexico/BajaNorte MST7MDT_MX America/Chihuahua, America/Hermosillo, America/Mazatlan, Mexico/BajaSur CST6CDT_MX America/Guatemala North America (Turks and Caicos) EST5EDT_TC America/Grand_Turk Additions Since 10g RTM EST5EDT_INDIANA America/Indiana/Indianapolis, America/Indiana/Marengo, America/Indiana/Vevay, America/Fort_Wayne, America/Indianapolis, America/Indiana/Knox, America/Knox_IN, US/Indiana-Starke, US/East- Indiana UCT-8_WA Australia/Perth, Australia/West IES-0880 User Manual Page 144...

Table of Contents