Advertisement

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS
CONGRATULATIONS—You are now the proud owner of one of the finest stoves in the world for your home —the
QUADRA-FIRE. Now, before installing your stove and building your first fire—record the serial number on the
warranty card. Serial number is located on the safety label on the rear of the stove.
PLEASE READ ALL OF THE OWNERS MANUAL AND SAFETY NOTES
1.
When installing your stove, particular attention should be paid to fire protection. If this unit is not properly installed, a
house fire may result. For your safety, follow the installation instructions and contact local building or fire officials
about restrictions and installation inspection requirements in your area.
2.
Never use gasoline or similar liquids to start a fire in this unit. Keep all such liquids well away from stove.
3.
During operation, if any part of the stove starts to glow, the stove is in an overfired condition. Close the air controls
completely until the glowing has stopped. OVERFIRING VOIDS WARRANTY.
4.
Cool ashes should be disposed of carefully, using a metal container.
5.
Do not burn wet or green wood. Store wood in dry location.
6.
Do not burn garbage, treated wood, or wood with salt (driftwood, etc.). Burning materials other than wood (including
charcoal) under adverse conditions may generate carbon monoxide in the home, resulting in illness or possible death.
7.
Do not permit creosote or soot to accumulate excessively in the chimney or inside the firebox.
8.
Check your chimney system thoroughly when installing into an existing metal or masonry chimney. Seek professional
advice if in doubt about its condition.
9.
Do not connect this unit to a chimney flue already serving another appliance.
10. Comply with all minimum clearances to combustibles as shown in this manual for this appliance.
11. Build fire on brick firebox floor. Do not use grates, andirons or other method to support fuel.
12. HOT WHILE IN OPERATION. Keep children, pets, clothing and furniture away. Contact can cause skin burns.
13. Do not connect to any air distribution duct or system.
14. RISK OF FIRE! Do not operate with stove door or ash removal system door open.
15. For further information refer to NFPA 211 (U.S.) or CAN/CSA-B365 (Canada).
16. WARNING: WHEN ASSEMBLING A UNIBODY APPLIANCE, USE ONLY GENUINE ALADDIN HEARTH
PRODUCTS MANUFACTURED COMPONENTS. USE OF ANY OTHER COMPONENTS WILL VOID YOUR
WARRANTY, AND COULD PRESENT A SERIOUS SAFETY HAZARD.
17. WARNING: DO NOT OPERATE YOUR QUADRA-FIRE STOVE BEFORE FULLY ASSEMBLING ALL
COMPONENTS. BURNING YOUR STOVE WITHOUT A PEDESTAL OR LEG KIT ATTACHED WILL VOID
YOUR WARRANTY, AND COULD PRESENT A SERIOUS SAFETY HAZARD.
401 N. WYNNE
COLVILLE, WA 99114
N o r t h A m e r i c a ' s B e s t
QUADRA-FIRE 3100 SERIES
IMPORTANT SAFETY NOTES:
SAVE THESE INSTRUCTIONS
(Revised 01/1999)
www.aladdinhearth.com
aladdin@aladdinhearth.com
Part #250-3500 #832-3050

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 3100 SERIES

  • Page 1 CONGRATULATIONS—You are now the proud owner of one of the finest stoves in the world for your home —the QUADRA-FIRE. Now, before installing your stove and building your first fire—record the serial number on the warranty card. Serial number is located on the safety label on the rear of the stove.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety label ............................3 Dimensions ............................4 Clearances to combustibles ........................ 6 Safety listing ............................7 Installation materials needed ......................7 Venting system ........................... 7 Chimney connector ..........................8 Chimney height/draft .......................... 8 Connection to a masonry chimney ..................... 8 1.
  • Page 3: Safety Label

    3100 SAFETY LABEL (found on back of stove) Serial No. Model: Quadra-Fire 3100 Manufactaured by: Page 3...
  • Page 4: Dimensions

    DIMENSIONS PEDESTAL MODEL 23" (584m m ) 24 1/2" (62 2m m ) 2 1/4" (57m m ) 9" (229m m ) 20 1/2" (52 1m m ) 26 3/8" (67 0m m ) FIGURE 1a LEG MODEL 23" (584m m ) 24 1/2"...
  • Page 5 DIMENSIONS STEP TOP PEDESTAL MODEL 26 5/8" (676m m ) 23 7/8" (606m m ) 24 5/8" (626m m ) 13 11/16" (348m m ) 2 13/16" (72m m ) 9" (229m m ) 4 5/16" (110m m ) FIGURE 2a 20 1/2"...
  • Page 6: Clearances To Combustibles

    18”(457) 8”(203) Alcove Standard Note 2 & 3 12”(305) 26”(661) 10”(254) 18”(457) 8”(203) Minimum clearances to Combustible Materials (in inches and millimeters) for Quadra-Fire 3100 with top shield Chimney & Installation Clearance Connector Residential Standard Note 1 12”(305) 24”(610) 16”(406) 10”(254)
  • Page 7: Safety Listing

    SAFETY LISTING The Quadra-Fire 3100 is listed by OMNI-Test Laboratories, Inc. , Beaverton, Oregon, to UL 1482-83, (UM)84 HUD and ULC S627. It is also approved for mobile home installations with outside combustion air in the U.S. (see pages 15 and 16 for further details). For residential installations in Canada without an outside combustion air kit, a source of fresh air into the room must be provided.
  • Page 8: Chimney Connector

    NOTE: These are guidelines only, and may vary somewhat for individual installations. Your Quadra-Fire stove was designed for and tested on a 6” (152mm) chimney, 12’-14’ (3.66-4.27m) high, measured from the top of the stove. The further your stack height or diameter varies from this configuration, the probability of performance problems increases.
  • Page 9 The chimney must have a fire clay flue liner (or equivalent) with a minimum thickness of 5/8” (16mm) and must be installed with refractory mortar. There must be at least ½” (13mm) air space between the flue liner and the chimney wall (Figure 4). An equivalent liner must be a listed chimney liner system or other approved material.
  • Page 10 Remember that insulation must not contact the chimney. There must be air space around the chimney. Insulation must be 2” (50mm) or more from the chimney (Figure 6). FIGURE 6 A chimney must be the required height above the roof or other obstruction for safety and proper draft operation. The chimney must be a minimum of 3’...
  • Page 11: Thimble

    2. THIMBLE: An approved thimble must be used when the connection from the stove is made through a combustible wall to a masonry chimney. There are several methods you can use for connection through a combustible wall, two of which are illustrated in this manual. For additional methods, consult local building authorities or use the standards set forth in NFPA 211.
  • Page 12: 6" Solid Pack Chimney With Metal Supports

    FIGURE 9 Minimum 3 ½” (89mm) [4” (102mm) nominal] thick solid bricks are to be used. The fire clay liner (ASTM C35 or equivalent), 5/8” (16mm) wall thickness, must not penetrate into the chimney beyond the inner surface of the chimney flue liner and must be firmly cemented in place. If it is necessary to cut a hole in the chimney liner, use extreme care to keep it from shattering.
  • Page 13 First, build the frame for the thimble, making sure that it is no smaller than 14½” (368mm) diameter, which will maintain a 2” (50mm) air space around the chimney section. Attach the wall spacer to the chimney side of the frame.
  • Page 14: Connection To A Metal Prefabricated Chimney

    CONNECTION TO A METAL PREFABRICATED CHIMNEY When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed precisely. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass-through and “T” section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc.
  • Page 15: Mobile Home Installation

    MOBILE HOME INSTALLATION You must use a Quadra-Fire 3100 outside air kit (see page 16 for part numbers) for installation in a mobile home. Use of alternative material will void warranty. 1. An outside air inlet must be provided for combustion and be unrestricted while unit is in use.
  • Page 16: Outside Air Kit Installation

    OUTSIDE AIR KIT INSTALLATION 3100 LEG MODELS Part #831-1740 Front cover plate attaches to firebox bottom below ash lip with two ¼”-20 mounting screws. Mount rear air intake cover plate with two mounting screws. Install each side cover with two 8-32 screws. Floor installation: Cut a 3”...
  • Page 17: Pedestal And Leg Installation

    PEDESTAL/LEG KIT INSTALLATION WARNING: DO NOT OPERATE YOUR QUADRA-FIRE STOVE BEFORE FULLY ASSEMBLING ALL COMPONENTS. BURNING YOUR STOVE WITHOUT A PEDESTAL OR LEG KIT ATTACHED WILL VOID YOUR WARRANTY, AND COULD PRESENT A SAFETY HAZARD. PEDESTAL MODEL 1. Place protective pad or stove pallet on floor.
  • Page 18: Ash Removal System Installation

    ASH REMOVAL SYSTEM INSTALLATION 1. Remove ash removal system top and bottom cover plates by loosening nuts under stove. 2. Discard both plates. 3. Insert ash removal system grate into opening in firebox floor. 4. Continue with proper installation according to model you have purchased: pedestal or leg.
  • Page 19: Ash Removal System Operating And Cleaning

    ASH REMOVAL SYSTEM OPERATING AND CLEANING CAUTION: Do not operate stove with ash removal system door open. Store ash in metal container until hot embers have cooled completely. When stove is cool, open front door and brush most of the ash into the center of the firebox. Remember to leave ¼”...
  • Page 20: Operating Instructions

    In recent years there has been an increasing concern about air quality. Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve the situation, we at Quadra-Fire have developed cleaner-burning wood stoves that surpass the requirements for emissions established by our governing agencies.
  • Page 21: Blower Operating Instructions

    Here are a few tips on operating your Quadra-Fire stove to obtain maximum efficiency with lowest emissions: Regardless of desired heat output, when loading stove, burn your Quadra-Fire with both air controls wide open for a minimum of 15 minutes.
  • Page 22: Building A Fire

    OPERATING INSTRUCTIONS (cont.) BURNING GUIDELINES (cont.) MEDIUM: After a wood load has been burning on high for at least 15 minutes (longer for very large pieces or wet wood), close (pull out) the primary control (on the right side of the stove). Leave the secondary control (under the ashcatcher) open (pushed in).
  • Page 23: Maintenance

    NOTE: Remove all labels from glass before lighting the first fire in your stove. Quadra-Fire stoves are equipped with ceramic super heat-resistant glass, which can only be broken by impact or misuse. Do not slam stove door or impact the glass. When closing door, make sure that logs do not protrude against the glass.
  • Page 24: Door Handle Assembly And Glass Replacement

    Remove glass tabs and screws with a Phillips screwdriver (turn screws counterclockwise). 3. Lift glass frame pieces and glass out of the door frame. Lay new glass with fiberglass tape around it into the door frame, making sure the Quadra-Fire logo reads correctly to the outside.
  • Page 25: Baffle Removal And Installation

    Call a qualified chimney sweep or an authorized Quadra-Fire dealer for details. 1. Remove all ash from the firebox, and extinguish all 4.
  • Page 26: Brick Pattern

    BAFFLE REMOVAL AND INSTALLATION (cont.) 7. Keep the baffle tilted as you lift it out the door. 8. To install the baffle, repeat steps 2 through 7 in reverse. Be sure that the hole in the baffle is on its alignment pin on the rear shelf.
  • Page 27: Installation Of Optional Blower

    INSTALLATION OF OPTIONAL BLOWER Part #831-1700 The blower is shipped fully assembled and ready for installation. 1. Remove three ¼”-20 (3/8” hex head) bolts from blower cover, and remove nutbar. Discard nutbar. 2. Using bolts, attach blower to lower rear of stove, as shown. 3.
  • Page 28: Top Heat Shield Installation

    TOP HEAT SHIELD INSTALLATION 1. Unscrew and remove the rear heat deflector. 2. Attach the two “S” clips to the upper edge of the outer wall of the stove. Set top heat shield on stove and push down into “S” clips. 4.
  • Page 29: Accessories And Service Parts

    ACCESSORIES AND SERVICE PARTS ACCESSORIES 831-1650 Top shield, gold 831-0971 Top shield, black 831-1730 Outside air kit, pedestal 831-1740 Outside air kit, leg 831-1700 Blower 832-1091 Black door 832-1911 Trim door 832-0031 Gold door 831-1670 Ash removal system SERVICE PARTS 832-0420 Kaowool blanket 832-3010...
  • Page 30: Notes

    NOTES Page 30...
  • Page 31 NOTES Page 31...
  • Page 32: Warranty

    Aladdin Hearth Products. This new Quadra-Fire product must be installed by a competent, authorized service contractor. It must be installed and operated at all times in accordance with the Installation and Operating Instructions in this manual, as well as any applicable local and national codes.

Table of Contents