Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
R
If the information in these instructions is
not followed exactly, a fire could result
causing property damage, personal injury,
or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void
your warranty.
Comply with all minimum clearances to combustibles
as specified.
Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass and appliance will cause burns.
Do not touch glass until it is cooled
Use leather gloves when reloading fuel
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as appliance.
Alert children and adults to hazards of
high temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Fire Risk.
For use with solid wood fuel only.
Other fuels may over fire and generate
poisonous gases (i.e. carbon monoxide).
7033-361B
WARNING
WARNING
WARNING
November, 2021

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 31M-ACC-AU

  • Page 1 Over firing will void your warranty. MODEL NUMBER: • Comply with all minimum clearances to combustibles as specified. 31M-ACC-AU Failure to comply may cause house fire. WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
  • Page 2: Table Of Contents

    D. Clearances to Combustibles ......9 Quadra-Fire is a registered trademark of Hearth & Home Technologies.
  • Page 3: Important Safety Information

    NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice. The Quadra-Fire 3100 Millennium Australian Wood Appliance is Hardwood Certified. Particulate Emissions equaling 1.4 g/kg with a space heating efficiency of 71%.
  • Page 4: Getting Started

    Install Guide Getting Started B. Fire Safety A. Design and Installation Considerations To provide reasonable fire safety, the following should be Consideration must be given to: given serious consideration: Safety 1. Install at least one smoke detector on each floor of Convenience your home to ensure your safety.
  • Page 5: Tools And Supplies Needed

    E. Inspection of Appliance and Components To minimize the effects of negative air pressure: • Install optional outside air kit with the intake facing • Remove appliance and components from packaging prevailing winds during the heating season and inspect for damage. •...
  • Page 6: Install Checklist

    G. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this installation manual. _________________________________________________________________________________ Customer: ______________________________________________________________________________ Date Installed: ______________________________________________________________________________ Lot / Address: ________________________________________________________________________ Location of Appliance:...
  • Page 7: Dimensions And Clearances

    Dimensions and Clearances A. Appliance Dimensions NOTE: Flue Collar size is 152mm inside diameter (ID) 648mm 89mm 323mm 171mm 278mm 749mm 383mm 533mm Figure 7.1 - Front View Figure 7.2 - Top View 676mm 618mm 796mm 501mm Figure 7.3 - Side View 7033-361B November, 2021...
  • Page 8: Hearth Protection Requirements

    B. Hearth Protection Requirements C. Firebox Installation Quadra-fire 3100 Millennium ACC do not require a 1. If a separate floor protector is being used position insulating Floor Protector, as they are tested and comply now. Place the firebox on the floor protector to suit with the minimum Floor Protector requirements of AS/NZS the minimum installation clearances (Figures 9.1 and...
  • Page 9: Clearances To Combustibles

    D. Clearances to Combustibles MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in Millimeters Note: A, C, and F Dimensions are to the center of the flue collar 3100 Millennium AU Wood Appliance INSTALLATION DOUBLE WALL PIPE 1062 1197 1469 Figure 9.2 Figure 9.1 Figure 9.3 NOTE: Service Space In order to replace the tube channel assembly a clearance of 483mm is required on the right side of appliance in order...
  • Page 10: Chimney Systems

    Chimney Systems A. Locating Your Appliance & Chimney • Consider the appliance location in order to avoid floor Location of the appliance and chimney will affect and ceiling attic joists and rafters. performance. As shown in Figure 10.1 the chimney should: •...
  • Page 11: Minimum Height Of Flue System Exit

    B. Minimum Height of Flue System Exit 3000mm more than 3000mm or less 600mm 6000mm minimum 3000mm increase from 1000mm minimum until clear within 3000mm of flue top increase as necessary until nothing within 3000mm of fluetop any nearby structure Figure 11.1 NOTICE: NOTICE: Locating the appliance in a basement or...
  • Page 12: Chimney Termination Requirements

    C. Chimney Termination Requirements 9. Prepare the ceiling plate and place upside down over the flue spigot. Flue pipe installed crimp/narrow end down 10. Install the flue pipes by preferred method – either up or Outer casings installed crimped/narrow end up. down the outer casing.
  • Page 13: General Flue System Instructions

    This product was designed for and tested on a 152mm G. Proper Draft chimney, 427-488cm high, (includes appliance height) To be sure that your Quadra-Fire insert burns properly, the measured from the base of the appliance. The further your chimney draft (static pressure) should be approximately stack height or diameter varies from this configuration, the -2.54mm water column (W.C.) during a high burn and...
  • Page 14: Tested Flue Systems

    H. Tested Flue Systems , as per AS/NZS 2918:2001 ADD Cowl Casing Cover oversized casing cover minimum 25mm gap is necessary between flue pipe casing & Spider Bracket combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing Approved Flashing Roof Line...
  • Page 15: Un-Tested Flue Systems

    I. Un-Tested Flue Systems , as per AS/NZS 2918:2001, 4.6.3(b) ADD Cowl AS/NZS2918:2001 Casing Cover Un-tested flue with sloped ceiling Spider Bracket penetration greater than 30° from horizontal A = 25mm Approved Flashing 4.6.3(b) Fig 4.6 = downward distance of casing and 3 x ø...
  • Page 16: Appliance Set-Up

    Appliance Set-Up A. Outside Air Kit Installation WARNING A source of air (oxygen) is necessary in order for combustion to take place. Whatever combustion air is consumed by the fire must be replaced. Air is replaced via Fire Risk. air leakage around windows and under doors. In homes Asphyxiation Risk.
  • Page 17: Door Handle Assembly

    B. Door Handle Assembly Install spring handle using a counter-clockwise motion until the spring handle has a 51mm clearance from bend of door hand rod (Figure 17.1). 51mm clearance is required from bend in door handle rod to end of spring handle Spring handle Door handle...
  • Page 18: As/Nzs 2918:2001 General Notes

    AS/NZS 2918:2001 General Notes WARNINGS WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY, I.E.