Carrier AQUASNAP 30RB060-390 Controls, Start-Up, Operation, Service And Troubleshooting Instructions page 88

Air-cooled liquid chillers
Hide thumbs Also See for AQUASNAP 30RB060-390:
Table of Contents

Advertisement

ITEM
EXPANSION
DISP
DISPLAY CONFIGURATION
TEST
Test Display LED's
METR
Metric Display
LANG
Language Selection
UNIT
UNIT CONFIGURATION
TYPE
Unit Type
TONS
Unit Size
VAR.A Nb Fan on Varifan Cir A
VAR.B Nb Fan on Varifan Cir B
VAR.C Nb Fan on Varifan Cir C
HGBP
Hot Gas Bypass Control
60HZ
60 Hz Frequency
RECL
Heat Reclaim Select
EHS
Electrical Heater Stage
EMM
EMM Module Installed
PAS.E
Password Enable
Password Protection Must Be
Disabled to Change Password
PASS
Password
FREE
Free Cooling Select
PD4.D
Pro_Dialog User Display
BOIL
Boiler Command Select
VLT.S
VLT Fan Drive Select
RPM.F VLT Fan Drive RPM
MCHX
MCHX Exchanger Select
SERV
SERVICE CONFIGURATION
FLUD
Cooler Fluid Type
MOP
EXV MOP Setpoint
HP.TH
High Pressure Threshold
SHP.A
Cir A Superheat Setp
SHP.B
Cir B Superheat Setp
SHP.C
Cir C Superheat Setp
HTR
Cooler Heater DT Setp
EWTO
Entering Water Control
AU.SM Auto Start When SM Lost
BOTH
HSM Both Command Select
LLWT
Brine Min. Fluid Temp.
LOSP
Brine Freeze Setpoint
HD.PG Varifan Proportion Gain
HD.DG Varifan Derivative Gain
HD.IG
Varifan Integral Gain
HR.MI
Reclaim Water Valve Min
HR.MA Reclaim Water Valve Max
AVFA
Attach Drive to Fan A
AVFB
Attach Drive to Fan B
AVFC
Attach Drive to Fan C
APPENDIX A — LOCAL DISPLAY TABLES (cont)
MODE — CONFIGURATION
UNITS
RANGE
OFF/ON
US/METR
0=English
1=Espanol
2=Francais
3=Portugues
4=Translated
1=Air Cooled
2=Heat Pump
XXX (tons)
56 to 300
(nominal size —
refer to Table 1 for
unit modular
combinations)
X
0-6
X
0-6
X
0-6
0=Unused
1=Startup Only
2=Close Ctrl
3=High Ambient
NO/YES
NO/YES
0-4
NO/YES
DSBL/ENBL
XXX
1 to 0150
NO/YES
NO/YES
OFF/ON
NO/YES
XXXX
0 to 1200
NO/YES
1=Water
2=Brine
3=Low Brine
XX.X
40-60 F
(deg F/deg C)
(4.4-15.6 C)
XXX.X (psi/kPa) 500-640 psi
(3447 to
4412 kPa)
XX.X (F/C)
3-14 F
(1.7-7.8 C)
XX.X (F/C)
3-14 F
(1.7-7.8 C)
XX.X (F/C)
3-14 F
(1.7-7.8 C)
XX.X (F/C)
0.5-9 F
(0.3-5.0 C)
NO/YES
NO/YES
NO/YES
XX
–20-38 F
XX.X
–4-50 F
(deg F/deg C)
(–20-10 C)
XX.X
–10-10
XX.X
–10-10
XX.X
–10-10
XXX.X (%)
XXX.X (%)
NO/YES
NO/YES
NO/YES
WRITE
COMMENT
DEFAULT
STATUS
OFF
US
0
Heat pump not
1
supported
0: No low ambient
temperature head
pressure control
1:low ambient
temperature head
pressure control
0: No low ambient
temperature head
pressure control
1: low ambient
temperature head
pressure control
0: No low ambient
temperature head
pressure control
1: low ambient
temperature head
pressure control
1 is default for
0
med. temp.
brine units
(FLUD=2)
YES
NO
Not supported
0
NO
ENBL
0111
Not supported.
NO
Must be set to
NO
NO
Not supported.
OFF
Not supported.
NO
Not supported.
0
NO
Low Brine is
1
not supported.
50
609
9.0
9.0
9.0
2.0
(Number of
degrees added to
brine freeze set
point to enable
cooler heater.)
NO
NO
NO
34.0
2.0
0.4
0.2
20
100
Not supported.
NO
Not supported.
NO
Not supported.
NO
88
CCN
CCN
PAGE
TABLE
POINT
NO.
N/A
display_test
DISPCONF DISPUNIT
DISPCONF LANGUAGE
FACTORY
unit_typ
FACTORY
unitsize
66
FACTORY
varfan_a
FACTORY
varfan_b
FACTORY
varfan_c
FACTORY
hgbp_sel
17,
20-23
FACTORY
freq_60H
FACTORY
recl_opt
49
FACTORY
ehs_sel
FACTORY
emm_nrcp
65
FACTORY
pass_enb
FACTORY
fac_pass
FACTORY
freecool
FACTORY
pd4_disp
FACTORY
boil_sel
FACTORY
Vh_sel
FACTORY
Vh_rpm
FACTORY
mchx_sel
SERVICE1
flui_typ
17,
22-24
33,66,
67,69
SERVICE1
mop_sp
67
SERVICE1
hp_th
23,48
SERVICE1
sh_sp_a
67,69
SERVICE1
sh_sp_b
67,69
SERVICE1
sh_sp_c
67,69
SERVICE1
heatersp
51
SERVICE1
ewt_opt
33
SERVICE1
auto_sm
68
USER
both_sel
USER
Mini_Lwt
SERVICE1
lowestsp
23,24,
33,51,
66,69
SERVICE1
hd_pg
SERVICE1
hd_dg
SERVICE1
hd_ig
SERVICE1
min_3w
SERVICE1
max_3w
SERVICE3
set_drva
SERVICE3
set_drvb
SERVICE3
set_drvc