Carrier AQUASNAP 30RB060-390 Controls, Start-Up, Operation, Service And Troubleshooting Instructions page 84

Air-cooled liquid chillers
Hide thumbs Also See for AQUASNAP 30RB060-390:
Table of Contents

Advertisement

ITEM
EXPANSION
TEST
COMPRESSORS
T.REQ
Manual Sequence
CP.A1
Compressor A1 Output
CP.A2
Compressor A2 Output
CP.A3
Compressor A3 Output
CP.A4
Compressor A4 Output
HGB.A
Hot Gas Bypass A Output
CP.B1
Compressor B1 Output
CP.B2
Compressor B2 Output
CP.B3
Compressor B3 Output
CP.B4
Compressor B4 Output
HGB.B
Hot Gas Bypass B Output
CP.C1
Compressor C1 Output
CP.C2
Compressor C2 Output
CP.C3
Compressor C3 Output
CP.C4
Compressor C4 Output
HGB.C
Hot Gas Bypass C Output
QUIC
QUICK TEST MODE
Q.REQ
Quick Test Mode
EXV.A
Circuit A EXV % Open
EXV.B
Circuit B EXV % Open
EXV.C
Circuit C EXV % Open
FAN.A
Circuit A Fan Stages
FAN.B
Circuit B Fan Stages
FAN.C
Circuit C Fan Stages
SPD.A
Circ A Varifan position
SPD.B
Circ B Varifan position
SPD.C
Circ C Varifan position
FRV.A
Free Cooling Valve A
FRP.A
Refrigerant Pump Out A
FRV.B
Free Cooling Valve B
FRP.B
Refrigerant Pump Out B
FRV.C
Free Cooling Valve C
FRP.C
Refrigerant Pump Out C
RV.A
4 Way Valve Circuit A
RV.B
4 Way Valve Circuit B
BOIL
Boiler Command
HR1.A
Air Cond Enter Valve A
HR2.A
Air Cond Leaving Valv A
HR3.A
Water Cond Enter Valv A
HR4.A
Water Cond Leav Valve A
HR1.B
Air Cond Enter Valve B
HR2.B
Air Cond Leaving Valv B
HR3.B
Water Cond Enter Valv B
HR4.B
Water Cond Leav Valve B
PMP.1
Water Exchanger Pump 1
PMP.2
Water Exchanger Pump 2
CND.P
Reclaim Condenser Pump
CL.HT
Cooler Heater Output
CP.HT
Condenser Heater Output
CH.A1
Compressor A1 Heater
CH.A2
Compressor A2 Heater
CH.A3
Compressor A3 Heater
CH.A4
Compressor A4 Heater
CH.B1
Compressor B1 Heater
CH.B2
Compressor B2 Heater
CH.B3
Compressor B3 Heater
CH.B4
Compressor B4 Heater
CH.C1
Compressor C1 Heater
CH.C2
Compressor C2 Heater
CH.C3
Compressor C3 Heater
CH.C4
Compressor C4 Heater
HGB.A
Hot Gas Bypass A Output
HGB.B
Hot Gas Bypass B Output
HGB.C
Hot Gas Bypass C Output
Q.RDY
Chiller Ready Status
Q.RUN
Chiller Running Status
SHUT
Customer Shutdown Stat
CATO
Chiller Capacity 0-10v
ALRM
Alarm Relay
ALRT
Alert Relay
C.ALM
Critical Alarm Relay
*Place the Enable/Off/Remote Contact switch to the Off position prior to configuring T.REQ to ON. Configure the desired item to ON, then
place the Enable/Off/Remote Contact switch to the Enable position.
†Place the Enable/Off/Remote Contact switch to the Off position prior to configuring Q.REQ to ON. The switch should be in the Off position
to perform Quick Test.
APPENDIX A — LOCAL DISPLAY TABLES (cont)
MODE — SERVICE TEST
UNITS
RANGE
OFF/ON*
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON†
XXX (%)
0-100
XXX (%)
0-100
XXX (%)
0-100
X
0-6
X
0-6
X
0-6
XXX (%)
0-100
XXX (%)
0-100
XXX (%)
0-100
OPEN/CLSE
OFF/ON
OPEN/CLSE
OFF/ON
OPEN/CLSE
OFF/ON
OPEN/CLSE
OPEN/CLSE
OFF/ON
OPEN/CLSE
OPEN/CLSE
OPEN/CLSE
OPEN/CLSE
OPEN/CLSE
OPEN/CLSE
OPEN/CLSE
OPEN/CLSE
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
OFF/ON
XX.X (vdc)
OFF/ON
OFF/ON
OFF/ON
WRITE
COMMENT
STATUS
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
Not supported.
forcible
Not supported.
forcible
Not supported.
forcible
Not supported.
forcible
Not supported.
forcible
Not supported.
forcible
Not supported.
forcible
Not supported.
forcible
Not supported.
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
forcible
EMM
forcible
EMM
forcible
forcible
forcible
forcible
Not supported.
forcible
84
CCN TABLE
CCN POINT
N/A
N/A
service_test
N/A
comp_serv_a_1
N/A
comp_serv_a_2
N/A
comp_serv_a_3
N/A
comp_serv_a_4
N/A
hgbp_serv_a
N/A
comp_serv_b_1
N/A
comp_serv_b_2
N/A
comp_serv_b_3
N/A
comp_serv_b_4
N/A
hgbp_serv_b
N/A
comp_serv_c_1
N/A
comp_serv_c_2
N/A
comp_serv_c_3
N/A
comp_serv_c_4
N/A
hgbp_serv_c
N/A
N/A
test_request
N/A
exv_qck_a
N/A
exv_qck_b
N/A
exv_qck_c
N/A
fan_qck_a
N/A
fan_qck_b
N/A
fan_qck_c
N/A
hd_qck_a
N/A
hd_qck_b
N/A
hd_qck_c
N/A
fr_qck_1a
N/A
fr_qck_2a
N/A
fr_qck_1b
N/A
fr_qck_2b
N/A
fr_qck_1c
N/A
fr_qck_2c
N/A
rv_qck_a
N/A
rv_qck_b
N/A
boiler_qck
N/A
hr_ea_qck_a
N/A
hr_la_qck_a
N/A
hr_ew_qck_a
N/A
hr_lw_qck_a
N/A
hr_ea_qck_b
N/A
hr_la_qck_b
N/A
hr_ew_qck_b
N/A
hr_lw_qck_b
N/A
cpump_qck1
N/A
cpump_qck2
N/A
cond_pump_qck
N/A
coo_heat_qck
N/A
cond_htr_qck
N/A
cp_ht_qck_a1
N/A
cp_ht_qck_a2
N/A
cp_ht_qck_a3
N/A
cp_ht_qck_a4
N/A
cp_ht_qck_b1
N/A
cp_ht_qck_b2
N/A
cp_ht_qck_b3
N/A
cp_ht_qck_b4
N/A
cp_ht_qck_c1
N/A
cp_ht_qck_c2
N/A
cp_ht_qck_c3
N/A
cp_ht_qck_c4
N/A
N/A
N/A
N/A
ready_qck
N/A
running_qck
N/A
shutdown_qck
N/A
CAPT_010_qcK
N/A
alarm_qck
N/A
alert_qck
N/A
critical_qck
PAGE
NO.
51,74
51
51
51
51
51
51
51
51
51
51
51
51
51
75
50,51
50,51
50,51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents