6-2. Restoring to Factory Shipment Status

When a network configuration is changed, a wireless unit may be reconfigured in the first place or all of the
existing setup data may be deleted. Setup data can be restored (initialized) to Factory Shipment Status by 2
methods:
1. Using <INIT> Button

2. Using Setup Screen

If initialized, an access point and a client (slave) operate under "192.168.0.1" (Factory Shipment Status) and
"192.168.0.254" respectively.
If the network part of an IP address becomes different from that of a wireless unit due to initialization, access
will not be available. Change PC's IP address if necessary.
■ Using <INIT> Button
This initialization method resets all setup data to its factory shipment status.
Use the following steps to initialize if a setup screen of a wireless unit cannot be opened because an IP
address configured for a wireless unit is unknown or due to other reasons.
If, however, an IEEE802.11a (52CH-64CH, 100CH-140CH) channel is being specified, a unit waits for 60
seconds by the DFS function. Within 5 seconds after the POWER indicator stops flashing in 60 seconds,
press the <INIT> button for several seconds.
<To Initialize>
(1) Turn off power of a wireless unit.
(2) Detach all network devices connected to the wireless unit.
(3) Turn its power on while pressing the <INIT> button.(See below)
* Use a pen tip to press the <INIT> button.
24V Power
(+)
(-)
Activate 24V power while pressing the <INIT> button
(4) After [POWER] and [MODE] indicators started flashing at the same time
then [POWER], [MODE], [LAN], and [WIRELESS] indicators turned on,
release the <INIT> button.
* In case of a client (slave), the [RSSI] indicator turns on instead of
[MODE].
(5) Connect the wireless unit and PC then start Windows.
• [LAN] indicator turns on.
(6) Activate a WWW browser and specify a wireless unit IP address at facto-
ry shipment, which is "192.168.0.1" for an access point and
"192.168.0.254" for a client (slave).
Chapter 6. Replacement Procedure
Use a pen tip
6
6-5