Disabling Redundancy With Only One Module Present - HP ProCurve Management And Configuration Manual

Table of Contents

Advertisement

Redundancy (Switch 8212zl)
Turning Off Redundant Management
N o t e
ProCurve(config)# no redundancy management-module
The other management module may reboot and it will no longer be used for system
redundancy except in the case of a hardware failure of the active
management module. Do you want to continue [y/n]? y
ProCurve(config)# show redundancy
Settings
------- -
Mgmt Redundancy : disabled
Statistics
--------- -
Failovers
Last Failover :
Slot Module Description
---- ---------------------------------------- -------- ---------- ----------
1
ProCurve J9092A Management Module 8200zl Offline
2
ProCurve J9092A Management Module 8200zl Active
1
ProCurve J9093A Fabric Module 8200zl
2
ProCurve J9093A Fabric Module 8200zl
Figure 15-12. Results of Disabling Redundancy
15-22
Even if redundancy has been disabled, the specified management module will
become the active management module at the next system boot if you use the
redundancy active-management command. You are warned that you may not be
using current configurations. See "Setting the Active Management Module for
Next Boot" on page 15-9.
The second management module is enabled as the active management module
in the event of a hardware failure of the first management module.
Figure 15-12 shows that redundant management was disabled.
: 0

Disabling Redundancy With Only One Module Present

If you disable redundancy when there is only one management module in the
switch, and then you insert a second management module, the second module
will never go into standby mode. You must re-enable redundant management
using this command:
ProCurve(config)# redundancy management-module
Status
SW Version Boot Image
K.12.XX
K.12.XX
Enabled
Enabled
Primary
Primary

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procurve 8200zl

Table of Contents