To install the new battery:
NOTE: It may be necessary to remove the Server Feature Board from the unit to replace
the battery. Refer to "Expansion Slots" earlier in this chapter for instructions on removing
and installing expansion boards (including the Server Feature Board).
1. Follow the steps in "Removing the Access Panel" at the beginning of
the chapter.
2. Slide the battery out of the holder.
Figure 3-40. Removing the battery from the Server Feature Board
3. Slide the replacement battery into the proper position.
IMPORTANT: Positive polarity (+) must be positioned facing out.
4. Replace the server access panel and connect cables to the server.
5. Run RBSU to reconfigure your system after restarting by pressing F9
when prompted in the lower right corner of the screen.
For use with 1-GHz or greater Intel Pentium III processor-based server models only
Hardware Options Installation 3-39