RIKA INTEGRA II Instruction Manual page 26

Hide thumbs Also See for INTEGRA II:
Table of Contents

Advertisement

PROBLEM
Fan not running,
CAUSE(S):
● Stove has no power supply.
POSSIBLE SOLUTIONS:
● Check that the stove plug is connected to the
power supply. Ensure that the correc mains
voltage is available at the wall plug.
Caution: Remove mains plug!
PROBLEM
Soot or flue dust outside of the stove
CAUSE(S):
● Grate door open when stove is lit.
● Leaks in the flue system or flue lines.
POSSIBLE SOLUTIONS:
● Always keep the grate door closed and if
possible only open when the stove is not
operating.
● Rectify leaks in the extraction system (e.g. use
heat resistant aluminium adhesive strip, heat
resistant adhesive strip or heat resistant
silicon).
CAUTION: checks must only be carried out on the
control and cabling when no power is applied to the
stove. Only trained personnel may carry out repairs.
CONTROL OF ERROR MESSAGES
If the stove does not stop according to the program
(e.g. pellet container empty, over temperature
triggered,
lower
temperature
message, air sensor fault, combustion fault (e.g.
clogged combustion cavity, unsealed grate door,
broken glass in grate door, etc) the error message
"Err" (Error) appears on the display.
When an error message occurs the corresponding
cause must be rectified, the stove can then be re-
started by pressing "ON/OFF".
- 26 -
protection
error

Hide quick links: