11. FAULTS - CAUSES - SOLUTIONS
PROBLEM
The fire is burning with a weak, orangecoloured
flame. Pellets are building up in the fire pan,
window is covered in soot.
CAUSE:
● Inadequate combustion air
POSSIBLE SOLUTIONS:
● Ensure that the fire pan sits in the fire pan
holder correctly - the fire pan must fit tightly on
the fire pan holder.
● Remove any ash or clinker that is blockin the air
inlet openings, from the fire pan. If possible
change to a better quality pellet.
● Check if the flue gas outlet is blocked with ash
(see "Maintenance" page)
● Check if the air inlet channel or flue tube is
blocked
● Check the door seal for leaks
● Clean the impeller.
● Have the stove serviced by an authorised
specialist company (control adjustment, flue
gas fan).
PROBLEM
Fire goes out or the stove switches off
automatically
CAUSE(S):
● Pellet container is empty.
● Pellets were not fed in.
● Thermostatic switch (upper temperature limit)
triggered.
● Door leaking or not closed tightly.
● Poor pellet quality
● Pellet feed rate too low
● Thermostatic switch (lower temperature limit)
triggered.
POSSIBLE SOLUTIONS:
● Fill up pellet container
● See the following section "Pellets not fed in"
● Let the stove cool down for an hour and
then re-start
● See "Routine maintenance"
● Only use a pellet quality recommended by us
● Have your specialist dealer set the fuel
regulating device
PROBLEM
Pellets were not fed in.
CAUSE(S):
● Pellet container is empty.
● Conveyor drive or control PCB are faulty.
● Auger is blocked (objects, wood etc.)
POSSIBLE SOLUTIONS:
Check the container content. Add more
pellets if necessary.
Have your specialist check the faults and
change parts if necessary.
Clean the pellet container and the conveyor
auger.
PROBLEM
Stove runs for 21 minutes and then switches off.
CAUSE(S):
The flue gas has not reached the required
temperature.
Lower temperature limiter may need to be
replaced.
The line to the lower or upper temperature
limiter is faulty.
Control is faulty.
POSSIBLE SOLUTIONS:
Carry out a re-start if necessary.
Have a service technician replace the lower
temperature limiter and check the control.
Check the cabling, see block diagram (Fig. 6)
Check that there is a good connection between the
lines and the ends (clamps).
Caution: Remove mains plug!
- 25 -