FLUE GAS FAN HOUSING
This maintenance procedure should be carried out
dependent on the fire usage and the fuel used, as
frequently as required. In order to inspect the flue
gas fan and to clean it, remove four screws (see
drawing) and pull the motor out of the housing
carefully. Remove the flue dust from the fan and flue
gas outlets using a vacuum cleaner. When closing
care must be taken that there are no leaks.
Only carry out maintenance when the mains plug of
the fire has been removed from the socket.
Note:
All
motors
have
Lubrication is not required!
FUEL CONTAINER
Do not fill the container up again immediately
but remove residues (dust, chips etc.)
from the empty container using a vacuum
cleaner and the RIKA Ashbox.
Observe tightness of seals:
Parts not correctly sealed (e.g. after cleaning) may allow false
air to be suctioned in that may lead to incomplete combustion
in the trough and to backing-up of pellets to the chute.
(Burnback hazard)
DOOR SEAL
The state of the seals on the doors and glass should
be checked from time to time. Repair or replace the
seals dependent on the state.
every six months!
FLUE CONNECTION
Inspect and clean the connection. The collected flue
dust can have a negative effect on the fire
performance and represent a safety risk.
AIR SENSOR
The sensor should be maintained and cleaned by
an authorised service technician.
➧ Cleaning should be carried out using a soft
brush.
➧ Ensure the fitting is correct (the print plate must
be at the front).
sealed
ball
bearings.
- 24 -