3. TECHNOLOGY

Your new pellet stove is technologically advanced
as a result of years of tests in the laboratory and in
practice. The practical advantages of your pellet
stove are convincing:
OPERATING
OPERATIONAL RELIABILITY
The electronic monitoring device together with a
patented "air sensor" controls and regulates the
interplay of flue gas fan, conveyor auger, convection
fan and temperature.
This monitoring system guarantees an optimum
combustion and operating mode.
4. AUTOMATIC SAFETY FUNCTION

POWER FAILURE

After a short power failure the operating functions
that were set before the power failure are continued.
ON mode (manual operation). The control switches
to the ST (Start Phase) and the unit then re-runs in
ON operation. TM mode (automatic operation). The
control switches to the ST (Start Phase) and the unit
then re-runs in TM operation. SB mode (operational
readiness, standby operation). After two seconds
the control re-runs in the SB operation.
On power failure a small amount of smoke may be
shortly emitted. This does not represent a safety
risks.

OVERHEATING

A temperature safety switch (STL) switches the
stove off automatically if it overheats.
COMFORT
- 10 -
Your operating outlay is reduced to the most
necessary - this prevents operating faults whilst
working in an optimum fashion at the same time.
HIGHEST EFFICIENCY - LOWEST
EMISSIONS
A very large heat exchanger surface togetherwith
optimum combustion air control leads to very good
fuel usage. Finely metered pellet feed in an
optimised burner pot made from high quality grey
cast iron effects almost perfect combustion with very
good exhaust gas values - and this is guaranteed in
every operating phase.
A taking-out-of-service program (cleaning, follow-up
phase) is performed. The stove must be restarted
depending on the pre-set mode.
CAUTION: If overheating has occurred then
maintenance or cleaning work must be carried out.

LOW TEMPERATURE SWITCH OFF

If the stove cools down below a minimum
temperature, then the stove will switch off. This
switch off can also occur if pre-heating is too slow.
ELECTRIC
EXCESS-CURRENT
SHUT OFF
The device is protected against excess current by a
main fuse (on the rear of the device), (see
"Technical Specification").