APPENDIX 1.3
Always implement this adjustment if the main PCB ASSY or tape sensor PCB ASSY is
replaced, or if the result of the tape sensor inspection in the maintenance software tool
(QL1050tstSE.exe) is NG.
(1)
Connect the machine to your PC with the USB cable and turn the power supply
button ON.
(2)
Open the top cover ASSY.
(3)
Start the VR adjustment tool. (File name: QL1050tstVRAdjust.exe).
(4)
Write down the indication in the "Result" column in the VR adjustment tool.
Use Procedure of the VR Adjustment Tool
(QL1050tstVRAdjust.exe)
Fig. 25
Fig. 26
23