APPENDIX 1.3
Be sure to make this adjustment in any of the following cases:
- When you replace the main PCB ASSY
- When you replace the tape sensor PCB ASSY
- When you replace the media PCB ASSY
- When the tape sensor check in the maintenance software tool (ql570tstSE.exe) failed
<Operating Procedure>
(1) Start the VR adjustment tool. (File name: ql500tstVRAdjust.exe)
The following screen appears. (Fig. 33)
(2) Connect the machine to your PC with the USB cable and turn the ON/OFF button ON.
Note: When new hardware is detected and the "New hardware detection wizard" screen
appears, press the [Cancel] button.
Use Procedure of the VR Adjustment Tool
(ql500tstVRAdjust.exe)
Fig. 33
25