Electrical Control Interface Connection Group; J4 | Redundant Loop Connector; Table 2-5. J4 | Redundant Loop Connector Pinout - Comtech EF Data HPOD Installation And Operation Manual

C-, x-, ku-band high-power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
External Connectors and Pinouts
2.5

Electrical Control Interface Connection Group

2.5.1 J4 | REDUNDANT LOOP Connector

The J4 | REDUNDANT LOOP connector is located near the waveguide output and is used only in 
configurations where the SSPA controls waveguide switching.  
 
In  alternate  configurations,  such  as  "chain  switching",  another  system  block  or  external  M&C 
controls the waveguide switching. In this case, the connector remains unused and the protective 
cap should be left attached. The pinout specification is shown in Table 2‐5. 
 
 

Table 2-5. J4 | REDUNDANT LOOP Connector Pinout

Pin
Name
A
SW_CMD_A1
B
SW_CMD_COM
C
SW_CMD_A2
D
SW_IND_A1
E
SW_IND_A2
F
SW_CMD_B1
G
SW_CMD_B2
H
SW_IND_B1
J
SW_IND_B2
K
ADDR_1
L
ADDR_2
M
COM
N
RED_1_1
P
RED_1_2
R
SMFLT_1_IN
S
SMFLT_2_IN
T
SMFLT_OUT
U
RED_TXD
V
RED_RXD
2–7