HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Serial-Based Remote Product Management
5.3.4.6

Optional Message Arguments

Arguments are not required for all messages. Arguments are ASCII codes for the characters '0' to '9' (ASCII codes 48 to 57), period '.' 
(ASCII code 46), and comma ',' (ASCII code 44). 
5.3.4.7

End of Packet

Controller‐to‐Target – This is the 'Carriage Return' ([CR]) character (ASCII code 13). 
 
Target‐to‐Controller – This is the two‐character sequence 'Carriage Return', 'Line Feed' ([cr][lf]) (ASCII codes 13 and 10). Both 
indicate the valid termination of a packet. 
 
 