4.4.1 Telnet Operation via HyperTerminal

There is a disadvantage when using Windows Command‐line as a Telnet client. Since Command‐
line cannot translate a '\r' (i.e., carriage return or "CR") to a '\r\n' (i.e., CR+line feed "LF") for the 
messages  coming  from  Telnet  Server,  any  multi‐line  Target‐to‐Controller  response  (e.g.,  the 
response to the FRW? query) will be displayed as one line, with the latter lines overwriting the 
previous lines.  
 
In  order  to  view  the  full  response  messages,  Comtech  EF  Data  recommends  use  of  the 
HyperTerminal terminal emulation program, configured as a Telnet client. 
 
Configure HyperTerminal as follows: 
1. Ensure that the connection is 
made using TCP/IP (Winsock) 
instead of COM1 or COM2, as 
shown at the near right. 
 
2. ASCII Setup (File   Properties   
Settings   ASCII Setup): Check 
the "Send line ends with line 
feeds" option in the ASCII Sending 
section, and the "Append line 
feeds to incoming line ends" 
option in the ASCII Receiving 
section, as shown at the far right. 
 