HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
External Connectors and Pinouts
2.4
Ground and Power Connection Group
2.4.1 Ground Connection
An M4 stud is provided for connecting a common chassis ground among equipment.
2.4.2 J3 | AC IN Connector (AC Power Main)
Before applying AC power to the unit, make sure the waveguide output of the
amplifier is properly loaded or terminated. Failure to do so could lead to
equipment damage and excessive RF radiation levels.
The prime power input requirements are:
•
180 to 264 VAC
•
47 to 63 Hz
•
The power supply is power factor corrected. The total power required from the prime
power supply depends on the model used. Please refer to the respective data sheets.
The J3 | AC IN AC prime power input connector is a 3‐pin circular connector, type CA3102E20‐
19PB FMLB A. Ground Pin 'A' is of the first make/last break type. A mating connector
(CA3106E20‐19SB) is provided. The pinout specifications for J3 and its mate are provided in
Table 2‐3.
Table 2-3. J3 | AC IN Connector Pinout
Pin
A
B
C
2–5
Description
Ground
L2
L1
Revision 6
MN/HPOD.IOM