HPOD C, X-, or Ku-Band High-Power Outdoor Amplifier
Ethernet-based Remote Product Management
An MIB file is used for SNMP remote management of a unique device, and consist of a tree of 
nodes  called  Object  Identifiers  (OIDs).  Each  OID  provides  remote  management  of  a  particular 
function. 
 
Compile  these  MIB  files  in  a  user‐supplied  MIB  Browser  or  SNMP  Network  Monitoring  System 
server. 

4.3.2 SNMP Community Strings

In  SNMP  v1/v2c,  the  SNMP  Community  String  is  sent  unencrypted  in  the  SNMP 
packets. Caution must be taken by the network administrator to ensure that SNMP 
 
packets travel only over a secure and private network if security is a concern.  
The HPOD uses Community Strings as a password scheme that provides authentication before 
gaining access to the router agent's MIBs. They are used to authenticate users and determine 
access privileges to the SNMP agent. 
 
Type  the  SNMP  Community  String  into  the  user‐supplied  MIB  Browser  or  Network  Node  `
 
Management software. 
 
Three Community Strings are defined for SNMP access:  
 
 
 
For proper SNMP operation, the HPOD MIB files must be used with the associated 
version  of  the  HPOD  M&C.  Please  refer  to  the  HPOD  FW  Release  Notes  for 
information on the required FW/SW compatibility. 

4.3.3 SNMP Traps

The HPOD sends out SNMP traps both when a fault occurs and when it is cleared. 
 
1. The SNMP agent supports SNMP v1 and v2c.  
 
If SNMP v1 traps are to be used, then make sure to compile the traps file.
2.
 
Use the hpodSNMPTrapVersion OID to configure the type of traps that the HPOD will send.  
 
The HPOD uses these MIB2 v1 traps and v2 notifications: 
MIB2 SNMPv1 trap: Authentication Failure
MIB2 SNMPv2 notifications: Authentication Failure
 
Read Community 
 
Write Community  
Trap Community  
default = public 
default = private 
default = comtech 
5
1.3.6.1.6.3.1.1.5.5
4–3
Revision 6
MN/HPOD.IOM