Maximum Link Attempts; Relink Time-Out - Honeywell Xenon 1900 User Manual

Area-imaging scanner
Hide thumbs Also See for Xenon 1900:
Table of Contents

Advertisement

Event
Scanner reset due
to battery change
Scanner placed in
different base unit

Maximum Link Attempts

The Maximum Link Attempts setting controls the number of times the scan-
ner tries to form a connection with a base unit or PC. During the connec-
tion setup process, the scanner transmits in order to search for and
connect to a base unit. In order to prevent continuous transmissions that
could interfere with other users of the ISM band, the number of attempts to
connect is limited by this setting. After the maximum number of attempts is
reached, the scanner will not attempt to reconnect to the base unit. Press-
ing the trigger or placing the scanner in the cradle resets the attempt count
and the scanner will again try to link to the base unit. When set to zero, the
scanner will try to link until the Power Time-Out Timer setting (see
7) expires.
Scan the Maximum Link Attempts bar code, then scan the number of
attempts for the setting (from 0-100) from the inside back cover. Scan Save
to save the setting. Default = 0.

Relink Time-Out

Relink Time-Out controls the idle time between re-link attempts. An
attempt to link a scanner to a base unit typically lasts up to 5 seconds. This
is the time when the scanner is actually attempting to contact base unit.
Relink Time-Out controls the amount of time, in seconds, that elapses
between the end of one connection attempt and the start of the next.
Note: The length of time for an attempt depends on the number of scanners
connected to a base unit. An extra 7 seconds may be required when
a connection is successful.
Scan the Relink Time-Out bar code, then scan the number of seconds for
the setting (from 1-100) from the inside back cover. Scan Save to save the
setting. Default = 3 seconds.
Auto Reconnect On
Re-link occurs automatically.
Re-link to new base occurs automatically.
Maximum Link Attempts
Relink Time-Out
Auto Reconnect Off
page 4-