Auto Reconnect Mode
Auto Reconnect controls whether or not the scanner automatically begins
the re-link process when a loss of connection is detected. When the Auto
Reconnect On bar code is scanned, the scanner begins the re-link pro-
cess immediately, without user intervention. Default = Auto Reconnect On.
* Auto Reconnect On
The table below shows the results of the Auto Reconnect On and Off set-
tings:
Event
Scanner out of
range
Base reset
(firmware upgrade
or power cycle)
Scanner power
down due to Power
Time-Out Timer
setting (see
7)
Scanner reset due
to firmware
upgrade
3 - 26
Auto Reconnect On
Re-link occurs
automatically. If
maximum number of link
attempts (see
Link Attempts
3-27) is unsuccessful,
then the trigger must be
pulled or the scanner
must be placed in the
base unit to re-link.
Scanner behaves as if
out of range.
Trigger must be pulled or the scanner must be
placed in the base unit to re-link.
(Note: scanner re-links on power up, but powers
page 4-
on due to one of the above actions.)
Re-link occurs automatically.
Auto Reconnect Off
Auto Reconnect Off
The trigger must be
pulled to initiate re-
linking.
Maximum
on page
No attempt to re-link
made while base unit
is powered off.
Trigger must be
pulled to initiate re-
linking.