5.0 Power Requirements

Jacuzzi ® spas are designed to provide optimum performance and flex-
ibility of use when connected to the maximum electrical service listed
below. Minor circuit board modifications can be performed to allow your
new spa to accept an electrical service other than the factory 50 Amp
operation setting. Note: Refer to pages 35-36 for circuit board configura-
tion details or contact your authorized Jacuzzi dealer.
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
*
In 40A configuration, the heater will not operate while either jets
pump is running in high speed. Note: pump 2 runs only in high speed.
** In 50A configuration, the heater will not operate while both jet pumps
are running in high speed. Note: pump 2 runs only in high speed.
This is the factory setting.
*** In 60A configuration, the heater will operate while both jet pumps are
running in high speed. Note: pump 2 runs only in high speed.
All J-270/J-280 Models (60Hz)
240V/40A*
240 VAC
3
60Hz
26A
40A, 2-Pole
240V/50A**
240 VAC
3
60Hz
36A
50A, 2-Pole
240V/60A***
240 VAC
3
60Hz
45A
60A, 2-Pole