Adding Fault Tolerance to an Existing Drive
FastTrak100-Lite will create a mirrored array using an existing system drive with
data. You must assign the existing drive and another drive of same or larger
capacity to the Mirroring array. The BIOS will send the existing data to the new
blank drive.
WARNING: Backup any necessary data before proceeding.
Failure to follow this accepted PC practice could result in data
loss.
WARNING : If you wish to include your current bootable drive
using the Windows NT 4.x or Windows 2000 operating system
as part of a bootable Mirrored (RAID 1) array on your
FastTrak100-Lite, do NOT connect the hard drive to the
FastTrak100-Lite controller yet. You MUST install the Windows
NT4 or 2000 driver software first (see page 133) to this drive
while it is still attached to the regular IDE port. For all other
Operating Systems, proceed here.
1.
After assigning the drives to a Mirroring array, press <Ctrl-Y> keys to Save
your selection. The window below will appear.
Do you want the disk image to be duplicated to another? (Yes/No)
Y - Create and Duplicate
N - Create Only
2.
Press "Y" for the Create and Duplicate option. The window below will
appear asking you to select the Source drive to use. FastBuild will copy all
data from the Source drive to the Target drive.