Asynchronous Port Table, RS-232-like MIB

The asynchronous port table contains an entry for the COM port when the port is
configured for asynchronous operation. For the DSU/CSU, the entries in the table
that are counters (rs232AsyncPortEntry 6 –8) are used to collect statistics and are
not supported.
Asynchronous Port Table, "rs232AsyncPortBits" (rs232AsyncPortEntry 2)
This object specifies the number of bits in a character. Only the following values
are supported by the DSU/CSU.
Asynchronous Port Table, "rs232AsyncPortStopBits"
(rs232AsyncPortEntry 3)
This object specifies the number of stop bits supported. Only the following values
are supported by the DSU/CSU.
Asynchronous Port Table, "rs232AsyncPortParity" (rs232AsyncPortEntry 4)
This object specifies the parity used by the port. Only the following values are
supported by the DSU/CSU.
Asynchronous Port Table, "rs232AsyncPortAutoBaud"
(rs232AsyncPortEntry 5)
This object specifies the ability to automatically sense the input speed of the port.
Only the following value is supported by the DSU/CSU.
3162-A2-GB20-40
H
7 – 7-bit characters. Supported on the COM port only.
H
8 – 8-bit characters.
H
one(1) – One stop bit.
H
two(2) – Two stop bits. Supported on the COM port only.
H
one-and-half(3) – One and a half stop bits. Supported on the COM port only.
H
none(1) – No parity bit.
H
odd(2) – Odd parity. Supported on the COM port only.
H
even(3) – Even parity. Supported on the COM port only.