Output Signal Table, RS-232-like MIB

Generic-Interface MIB Extensions (RFC 1229)
3162-A2-GB20-40
This object contains entries for the output signals that can be asserted by the unit
for each of the synchronous data ports.
Output Signal Table – "rs232OutSigName" (rs232OutSigEntry 2)
This object contains the identification of a hardware output signal. Only the
following values are supported by the DSU/CSU.
H
cts(1) – Clear-To-Send.
H
dsr(4) – Data Set Ready.
Output Signal Table – "rs232OutSigState" (rs232OutSigEntry 3)
This object contains the current signal state. Only the following values are
supported by the DSU/CSU.
H
on(2) – The signal is asserted.
H
off(3) – The signal is not asserted.
Output Signal Table – "rs232OutSigChanges" (rs232OutSigEntry 4)
This object is not supported by the DSU/CSU.
This generic-interface MIB is an experimental MIB that provides extensions to the
generic interface group defined in MIB II. This MIB describes three tables:
H
Generic Interface Extension Table
H
Generic Interface Test Table
H
Generic Receive Address Table
Only the generic interface test table is supported by the DSU/CSU. This table is
supported for the network interface only.
August 2000