Generic Interface Test Table, Generic Interface Mib - Paradyne 3162 User Manual

Hewlett-packard acculink dsu / csu user's guide 3162
Hide thumbs Also See for 3162:
Table of Contents

Advertisement

SNMP MIB Objects

Generic Interface Test Table, Generic Interface MIB

E-22
The test table provides access to additional tests (loopbacks and pattern tests)
that are not in the interface group of MIB II.
Generic Interface Test Table – "ifExtnsTestType" Object (ifExtnsTestEntry 4)
This object is a control variable used to start and stop operator-initiated tests on
the interface. It provides the capability to:
H
Start/stop the Monitor QRSS test pattern on the network interface.
H
Start/stop the Send QRSS/511 test pattern on a synchronous data port.
H
Start sending a V.54/FT1 UP/DOWN code to the remote unit for a
synchronous data port.
H
Start/stop the Monitor QRSS/511 test pattern on a synchronous data port.
H
Start/stop the DCLB/DTLB loopback test on a synchronous data port.
The following object identifiers are used to control the tests on the interface.
H
noTest – Stops the test in progress on the interface.
H
testFullDuplexLoopBack – Initiates a DCLB on the interface. Only supported
for the data ports.
H
testLoopDTLB – Initiates a DTLB on the interface. Only supported for the
data ports.
H
testMonQRSS – Initiates a Monitor QRSS test on the interface. Supported for
the data ports and the network interface.
H
testMon511 – Initiates a Monitor 511 test on the interface. Only supported for
the data ports.
H
testSendQRSS – Initiates a Send QRSS test on the interface. Only supported
for the data ports.
H
testSend511 – Initiates a send 511 test on the interface. Only supported for
the data ports.
H
testSendV54Up – Sends a V54 up code to the remote unit. Only supported
for the data ports.
H
testSendV54Down – Sends a V54 down code to the remote unit. Only
supported for the data ports.
H
testSendFT1Up – Sends a FT1 up code to the remote unit. Only supported
for the data ports.
H
testSendFT1Down – Sends a FT1 down code to the remote unit. Only
supported for the data ports.