Installation

Insert Clearances

Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture
and draperies.
Max. 8"

Mantel Clearances

The mantel must be a minimum 10" above the face and a maximum 8" deep.
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed in this manual.

Face Sizing

Avalon Rosario DVL
26"
35-3/4"
Lopi Discovery DVL
26"
35-3/4"
Travis Industries
Min. 8-1/2"
Side Facing
Min. 6"
12" Min. (from fireplace opening)
Avalon
Cambridge
37-5/8"
DVL
36-3/4"
25-7/8"
2"
FPX Arched
FPX Artisan
NOTE: Artisan faces
vary in size.
3-1/2"
Radius = 45"
26-1/2"
Access
Door
34-3/4"
4 0 4 1 0 2 8
(for qualified installers only)
Min. 10"
See "Face
Sizing" Below
Min. 6"
See "Face
Sizing" Below
2-3/8"
2-1/4"
Avalon
Craftsman
27-1/2"
27-1/2"
27"
16-1/2"
36"
* The decorative braces protrude 1/4"
FPX 34
Rectangular
Bevel
26-1/2"
34-3/4"
Access
Door
Side
Wall
The non-combustible hearth
must be as wide as the face
and extend to both sides.
Avalon
Avalon
Victorian DVL
Rawhide
35-3/4"
FPX 34
Architectural
Faces
27-7/8"
Access
Door
33-5/8"