Vent Installation; Vent Location; Vent Configurations - Travis Industries DVL EF Insert Owner's Manual

Table of Contents

Advertisement

Installation
1 2

Vent Installation

Exhaust (4")

Vent Location

Vent
Configurations
Travis Industries
(for qualified installers only)
Inlet (3")
4" dia. Gas
Liner
Inlet & Exhaust Re-Line
Exhaust
4" dia.
Gas Liner
Z.C. (Metal) firebox
NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.
4 0 4 1 0 2 8
Termination Cap
(Simpson Part # 991)
3" dia. Gas
Liner
6-5/8" to 3" & 4" Co-
Linear Adapter (Travis
Part # 98900124)
Inlet
Exhaust
Center Line
Exhaust (4" Dia.)
2-1/4"
13-1/4"
Direct Vent Cap
(part # 991)
6-5/8" to 3" & 4" Colinear
Adapter & Flashing
(Travis Part # 98900124)
Inlet
3" dia. Gas Liner
Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.
Suggestion:
Paint the fireplace cavity
with latex paint to eliminate
the possibility of odors from
the fireplace circulating into
the room.
Apply high-temperature
silicone to the liners on
both ends and secure
with 2 screws.
Inlet (3" Dia.)
13-7/8"
2"
16"
Exhaust Only Re-Line
(recommended)
Any cracks or
damage inside the
chimney must be
repaired.
The block-off plate mus
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.
Block-Off Plate
(non-combustible
materials)
Inlet
Masonry Fireplace
1 0 0 - 0 1 1 5 1
Fireplace
Opening
Exhaust
4" dia. Gas Liner

Advertisement

Table of Contents
loading

Table of Contents