Travis Industries DVL EF Insert Owner's Manual page 33

Table of Contents

Advertisement

4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
Lift the pilot hood
a
off the pilot
assembly.
5
Install the logs and embers.
6
Replace glass and face.
7
Remove the regulator from the front of
the gas control valve. Replace with the
propane regulator, using the new
gasket and screws included with the
regulator. NOTE: Leak test this
area after the heater is installed,
gas is connected, and the main
burner is lit.
8
Make the gas line connection, bleed the
gas line (if applicable), start the heater
and thoroughly leak-test all gas
connections and the gas control valve.
Check the pilot. Adjust if necessary.
WARNING:
When lighting or re-lighting
the pilot, the glass must be
removed (see page 17).
To adjust the pilot flame, turn this screw. Clockwise
lowers the flame while counter-clockwise raises it.
Travis Industries
Optional Equipment
Use a hex wrench to
b
unscrew the orifice.
5/32" Hex
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
Standard
Screwdriver
4 0 4 1 0 2 8
Remove the orifice and replace with the LP orifice. Screw the
c
orifice all the way in and replace the pilot hood.
a
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
c
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
Screwdriver
(or T-20 Torx)
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
Orifice Identification:
LP (Propane) Orifice
35
35
NG (Natural Gas) Orifice
62
b
Remove and discard the
regulator, diaphram, spring
and center post.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
d
Place the LP
label on the base
near the gas
control valve.
1 0 0 - 0 1 1 5 1
3 3

Advertisement

Table of Contents
loading

Table of Contents