SATO GL4xxe Series Operator's Manual page 117

Gl4e series
Hide thumbs Also See for GL4xxe Series:
Table of Contents

Advertisement

MENU
IBM Translation
Disable*
Slash Zero
Font Based*
EURO Symbol
0x0*
Preparsing data
Disable*
Status on <ETX>
Enable*
Cutter Cmd (c)
Process*
PwrUpMod Cmd (C)
Process*
EOP Dist Cmd (D)
Process*
Intens. Cmd (d)
Process*
GL408-412e Operator's Manual
Unit 4: Printer Configuration
IGL EMULATION MODE (TABLE 4-14)
Select whether the data sent to the printer is translated as standard ASCII or EBCDIC. Many IBM
Mini/Main-Frame computers use EBCDIC which does not directly translate to ASCII.
• Disable - factory default. The IBM version of the selected character will not be used.
• Enable - the IBM version of the selected character set will be used.
This menu determines if a zero numeral character wil be printed with a diagonal slash overlayed.
• Font Based - factory default. Zero characters will print with a slash if the selected font type
designates that it has one. This mimics IPL3 printers where not all fonts contain a slashed
zero.
• Disable - factory default. Zero characters are never printed with a slash.
• Enable - all zero characters will be printed with a slash, independent of the selected font.
This menu defines the code page position that contains the the Euro symbol.
The factory default is 0x0.
Select whether the data is to be processed as it is received or if the printer is to wait until the
entire job has been sent prior to any commands being processed. This menu determines if the
data preparser will be active or inactive.
• Enable - factory default. The data received from the host is preprocessed to quickly respond
to the immediate commands.
• Disable - the data is processed synchronously; the commands are not processed until all
preceding commands have been processed.
This menu determines if a printer status message will be returned to the host on receipt of the
block terminator <ETX>. This is implemented only for serial interface, X-On/X-Off, or Intermec
protocol.
• Disable - factory default. Will not send status message.
• Enable - will send status message.
Cutter Command. This menu defines if the <ESC>SIc command which enables or disables the
cutter assembly is acknowledged.
• Process - factory default. Acknowledges cutter commands.
• Ignore - does not acknowledge cutter commands.
Power Up Mode Command. This menu defines if the <ESC>SIC command which selects the
Emulation or Advanced power up mode is acknowledged.
• Process - factory default. Acknowledges the commands.
• Ignore - does not acknowledge the commands.
End-Of-Print Distance Command. This menu defines if the <ESC>SID command is
acknowledged.
• Process - factory default. Acknowledges the commands.
• Ignore - does not acknowledge the commands.
Intensity Command. This menu defines if the <ESC>SId command which sets print darkness is
acknowledged.
• Process - factory default. Acknowledges the commands.
• Ignore - does not acknowledge the commands.
DESCRIPTION
4-80

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gl412eGl408eGl408

Table of Contents