Cisco uBR-3x10 Hardware Installation And Cabling Manual page 114

Rf switch
Table of Contents

Advertisement

Troubleshooting the Installation and Setup
Figure 6-1
Turn on
verifies controller
Troubleshooting the Power Subsystem
Check the following to help isolate a problem with the power system.
Cisco uBR-3x10 RF Switch Hardware Installation and Cabling Guide
6-2
Troubleshooting Flowchart
Power
AC or DC
system
supply
LED on
power
Controller
and switch card
LEDs on
Set user
defined IP
ERROR
Y
LEDs on switch
address
cards off
Hook up
controller to
network
Server
Troubleshoot
N
network
operating
installation
Y
End
Does the POWER LED come on when system power is turned on? If not:
AC—check to ensure that the AC power cord is plugged in to the power supply and the power
source (wall or power strip).
DC—verify that the –48 and +48-V leads are correctly attached to the power supply.
Verify that the system is properly grounded.
Ensure that the voltage selection switch is in the appropriate AC or DC position.
If you are unable to resolve the problem, see the
page 12
for information on contacting Cisco technical assistance.
Troubleshoot
N
power
subsystem
Troubleshoot
N
controller
switch card
subsystems
Y
Replace cards
N
with ERROR
LED on
Server
verifies controller
operating
Y
"Obtaining Technical Assistance" section on
Chapter 6
Power
N
supply
LED on
Controller
N
and switch card
LEDs on
Y
ERROR
N
LEDs on switch
cards off
Y
Obtain
N
technical
assistance
End