Cisco uBR-3x10 Hardware Installation And Cabling Manual page 106

Rf switch
Table of Contents

Advertisement

Connecting the Cables (Cisco uBR-MC28x Line Card)
Figure 5-14
Cabling DS Ports to the Input Ports on the Upconverter
This section describes cabling from the Cisco uBR7246VXR line cards DS ports to the upconverter.
The Cisco uBR-MC28U cable interface line cards have onboard upconverters and are cabled directly to
Note
the DS ports (F, M, or G) on the RF switch.
Equipment
To cable the DS ports to the upconverter, complete the following steps. Refer to
page
Connect the cables to the downstream connectors (DS0, DS1) on the line cards (LC1–LC4).
Step 1
Step 2
Secure the cables with cable wrap, and run the cable bundles up the right side of the equipment rack.
Step 3
Pull the cable bundle through the space between the VXR1 router and the RF switch. Add a 10-dB
attenuator to the DS cables, if necessary.
Step 4
Connect the cables to the input ports (top) on the upconverter.
Step 5
Repeat Step 1 through Step 4 for each DS0 and DS1 port on the Cisco uBR7246VXR routers (VXR2
through VXR5).
Figure 5-15 on page 5-21
Cisco uBR-3x10 RF Switch Hardware Installation and Cabling Guide
5-20
Cabling the Protect Line Cards (MC28C)
5 cable bundles —(F-connector to F-connector—multicolor)
5-21, and
Table
5-15,
Table
shows cabling for the upconverter.
From the DS ports of the line cards to the upconverter—multicolored cables
From the upconverter to the RF switch—gray and brown cables
Chapter 5
Cabling the RF Switch With the Cisco uBR7246VXR CMTS
P1A-P1H
LC2
LC4
5-16, and
Table 5-17 on page
P2A-P2H
RFS-2
LC1
RFS-1
LC3
Figure 5-15 on
5-22.