Appendix A
Specifications for PCI-MIO-16XE-10, PCI-6031E, PCI-6032E, and PCI-6033E
RTSI
Calibration
Bus Interface
Power Requirement
Physical
PCI E Series User Manual
Accuracy ............................................ ±1% of fullscale range
Digital Trigger
Compatibility ..................................... TTL
Response ............................................ Rising or falling edge
Pulse width......................................... 10 ns min
Trigger Lines...................................... 7
Recommended warm-up time.................15 min
Calibration interval ............................ 1 year
External calibration reference ............ >6 and <9.999 V
Onboard calibration reference
Level ........................................... 5.000 V (±2.0 mV) (actual value
Temperature coefficient............... ±0.6 ppm/°C max
Long-term stability ...................... ±6 ppm/
Type ................................................... Master, slave
+5 VDC (±5%) ................................... 1.5 A
Power available at I/O connector........ +4.65 to +5.25 VDC at 1 A
Dimensions
(not including connectors) ................. 33.8 by 9.9 cm (13.3 by 3.9 in)
I/O connector
PCI-MIO-16XE-10,
stored in EEPROM)
A-20
1 000 h
© National Instruments Corporation