Sony DSR-DR1000 Operating Instructions Manual page 101

Video disk recorder
Hide thumbs Also See for DSR-DR1000:
Table of Contents

Advertisement

If such an alarm message appears, a connection or
operation error may have been made, or condensation on
heads may have occurred. Follow the direction indicated
on the monitor screen.
Alarm message on monitor screen
(Cause)
A non-standard signal is being used for
input video.
A non-standard ref. signal is being used
for REF. VIDEO.
Abnormal settings selected in setup
menu.
Audio mixing mode cannot be changed
during recording.
Audio REC (recording) mode cannot be
changed during recording.
Counter mode is selected.
Input selection cannot be changed in
REC (recording) mode.
Input signal does not conform to
DVCAM/DV format.
Input signal is 625/50. (For DSR-
DR1000)
Input signal is 525/60. (For DSR-
DR1000P)
Input video is not detected.
Input video signal does not synchronize
with REF. VIDEO signal.
Invalid subclip.
MODE CANNOT BE CHANGED
DURING DUAL RECORDING.
Moisture has been detected.
Rec inhibit mode is selected.
Remote mode is selected.
Simultaneous recording and playback.
TC EXTERNAL is selected.
TCG REGEN mode is selected.
Note
To display alarm messages on the monitor screen, it is
necessary for the monitor to be connected to the SUPER
connector, and set the following menu items to ON.
• CHARA. DISPLAY (see page 68)
• ALARM (see page 69)
• REF ALARM (see page 69)
Alarm messages and associated directions
Direction
Use a standard signal.
Use a standard signal.
Correct the setup menu settings. Contact your Sony
dealer if this alarm message appears again after
making corrections.
Use the COUNTER SELECT button to light the TC or
U-BIT time data type indicator in the display section.
Check the VIDEO indicator in the INPUT signal
display section and supply an appropriate video
signal.
Use a reference video signal.
There is an invalid subclip setting, for example a Mark
Out point before a Mark In point. Correct the setting.
To exit simultaneous recording and playback mode,
press the R button in the PANEL SELECT section to
stop recording and then press the R button again so
that the button goes out.
Keep the power on and wait until this alarm message
disappears.
Set the REC INHIBIT menu item (see page 67) to
OFF.
Set the LOCAL/REMOTE switch to LOCAL.
Stop the unit by pressing the STOP button and then
switch with the buttons in the PANEL SELECT
section.
Set the TC MODE menu item (see page 70) to INT
PRESET.
Set the TC MODE menu item (see page 70) to INT
PRESET.
Alarm message in time
counter display
VIN NON-STD
REF NON-STD
ILL. SETUP!
REC mode!
REC mode!
CNT mode!
REC mode!
Unknown Sig
625/50 sig! (For DSR-
DR1000)
525/60 sig! (For DSR-
DR1000P)
No INPUT!
ILL. REF!
CLIP set !
Dual REC !
HUMID!
REC INHI.!
REMOTE!
Dual Rec !
TC EXT!
REGEN mode!
Troubleshooting
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsr-dr1000p

Table of Contents