B–36
ModBus Data Listing
The following table lists the holding registers for the "C" Group Intelligent Input
Functions.
Func.
Code
C001
Terminal [1] function
C002
Terminal [2] function
C003
Terminal [3] function
C004
Terminal [4] function
C005
Terminal [5] function
C006
Terminal [6] function
C011
Terminal [1] active state R/W Select logic convention, two
C012
Terminal [2] active state R/W
C013
Terminal [3] active state R/W
C014
Terminal [4] active state R/W
C015
Terminal [5] active state R/W
C016
Terminal [6] active state R/W
C021
Terminal [11] function
C022
Terminal [12] function
C026
Alarm relay terminal
function
C028
[AM] signal selection
C031
Terminal [11] active
state
C032
Terminal [12] active
state
C036
Alarm relay active state
I
"C" Group Intelligent Terminal Functions
Name
R/W
R/W
R/W
R/W
R/W
See
R/W
R/W
option codes:
00... normally open [NO]
01... normally closed [NC]
R/W
R/W
Configuration" on page 3–
R/W
R/W Two available functions:
00... Actual motor speed
01... Motor current
R/W Select logic convention, two
option codes:
00... normally open (NO)
01... normally closed (NC)
R/W Select logic convention, two
option codes:
00... normally open (NO)
01... normally closed (NC)
R/W Select logic convention, two
option codes:
00... normally open (NO)
01... normally closed (NC)
Description
"Input Terminal Config-
uration" on page 3–41
"Output Terminal
See
46
Network Data
Reg.
Range
Res.
00A7h 0, 1, 2, 3,
—
4, 5, 6, 7,
00A8h
8, 9, 11,
12, 13,
00A9h
15, 16,
00AAh
18, 19,
20, 21,
00ABh
22, 23,
00ACh
24, 27,
28, 29,
31, 50,
51, 255
00ADh
0, 1
—
00AEh
0, 1
—
00AFh
0, 1
—
00B0h
0, 1
—
00B1h
0, 1
—
00B2h
0, 1
—
00B3h
—
0, 1, 2, 3,
00B4h
4, 5, 6, 7,
8, 9
00B5h
00B7h
0, 1
—
00B8h
0, 1
—
00B9h
0, 1
—
00BAh
0, 1
—