The jog speed setting is used whenever the Jog command is active. The jog speed setting
range is arbitrarily limited to 10 Hz, to provide safety during manual operation. The
acceleration to the jog frequency is instantaneous, but you can choose from three modes
for the best method for stopping the jog operation.
"A" Function
Func.
Name /
Code
SRW Display
A020 Multi-speed frequency
setting
SPD 00s 0000.0Hz
A220 Multi-speed frequency
setting, 2nd motor
2SPD00s 0000.0Hz
A021
Multi-speed frequency
to
settings
A035
(for both motors)
SPD 01s
000.0Hz
SPD 02s
000.0Hz
SPD 03s
000.0Hz
SPD 04s
000.0Hz
SPD 05s
000.0Hz
SPD 06s
000.0Hz
SPD 07s
000.0Hz
SPD 08s
000.0Hz
SPD 09s
000.0Hz
SPD 10s
000.0Hz
SPD 11s
000.0Hz
SPD 12s
000.0Hz
SPD 13s
000.0Hz
SPD 14s
000.0Hz
SPD 15s
000.0Hz
A038 Jog frequency setting
Jog-F
001.00Hz
A039 Jog stop mode
Jog-Mode
FRS
Description
Defines the first speed of a
multi-speed profile, range is
0.0 / start frequency to 400 Hz
A020 = Speed 0 (1st motor)
Defines the first speed of a
multi-speed profile for 2nd
motor, range is 0.0 / start
frequency to 400 Hz
A220 = Speed 0 (2nd motor)
Defines 15 more speeds,
range is 0.0 / start frequency
to 400 Hz.
A021= Speed 1...
A035 = Speed 15
A021
A022
A023
A024
A025
A026
A027
A028
A029
A030
A031
A032
A033
A034
A035
Defines limited speed for jog,
range is 0.00 / start frequency
to 9.99 Hz
Define how end of jog stops
the motor; three options:
00... Free-run stop
01... Controlled deceleration
02... DC braking to stop
SJ200 Inverter
Defaults
Run
Mode
–FEF
–FU
Edit
(EU)
(USA)
0.0
0.0
0.0
0.0
see
see
next
next
row
row
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
1.00
1.00
00
00
3–15
Units
Hz
Hz
Hz
Hz

Advertisement

Table of Contents
loading

Table of Contents