Set The Motor Base Frequency; Set The Avr Voltage Setting - Hitachi SJ200 Series Instruction Manual

Single-phase input 200v class; three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for SJ200 Series:
Table of Contents

Advertisement

2–30
Using the Front Panel Keypad
Set the Motor Base Frequency - The motor is designed to operate at a specific AC
frequency. Most commercial motors are designed for 50/60 Hz operation. First, check
the motor specifications. Then follow the steps below to verify the setting or correct it
for your motor. DO NOT set it greater than 50/60 Hz unless the motor manufacturer
specifically approves operation at the higher frequency.
(Starting point)
Press the
Press the
Press the
Press the
CAUTION: If you operate a motor at a frequency higher than the inverter standard
default setting (50Hz/60Hz), be sure to check the motor and machine specifications with
the respective manufacturer. Only operate the motor at elevated frequencies after getting
their approval. Otherwise, there is the danger of equipment damage.
Set the AVR Voltage Setting - The inverter has an Automatic Voltage Regulation (AVR)
function. It adjusts the output voltage to match the motor's nameplate voltage rating. The
AVR smooths out fluctuations in the input power source, but note that it does not boost
the voltage in the event of a brown-out. Use the AVR setting (A082) that most closely
matches the one for your motor.
• 200V Class: 200 / 215 / 220 / 230 / 240 VAC
• 400V Class: 380 / 400 / 415 / 440 / 460 / 480 VAC
TIP: If you need to scroll through a function or parameter list, press and hold the
2
key to auto-increment through the list.
To set the motor voltage, follow the steps on the following page.
Action
key once.
1
key.
FUNC.
or
key as needed.
2
1
STR
key.
Display
Func./Parameter
A 0 0 2
Run command source setting
A 0 0 3
Base frequency setting
6 0
Default value for base frequency.
US = 60 Hz, Europe = 50 Hz.
or
5 0
6 0
Set to your motor specs (your
display may be different)
A 0 0 3
Stores parameter, returns to "A"
Group list
or
1