Avaya G700 Installing Manual page 487

Media gateway and media server
Hide thumbs Also See for G700:
Table of Contents

Advertisement

which interface you want the file sync to use. Avaya recommends the use of the
customer LAN for file sync.
Note:
The CLAN boards must be TN799DP running version 5 or greater firmware. Be
Note:
sure to check the firmware version for these boards on the S8500 or
S8700-series. For information on how to upgrade the firmware on the S8500 or
S8700-series, please see the "Upgrading firmware on programmable TN circuit
packs," in Upgrading, Migrating, and Converting Avaya Media Servers and
Gateways, 03-300412.
12. If you clicked the LSP option and the primary controller is an S8300 or S8400 Media Server,
simply enter the IP address of the S8300 server.
13. Click Continue.
The Ethernet Adjuncts screen appears.
Ethernet Adjuncts Screen
14. In the Number of UPS Units field, select the number of Uninterruptible Power Supplies
(UPS) units connected to the S8300 Media Server.
This number is usually 0 or 1.
15. If you enter 1 in the Number of UPS Units field, enter its IP address in the UPS 1 IP
Address field.
The system will use this address to trap power loss signals from the UPS.
16. (Optional) If you enter 1 in the Number of UPS Units field, enter the SNMP community
strings for the UPS in the SNMP GET and SET fields.
Install the S8300
Issue 9.1 June 2006
487

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8300

Table of Contents