Motor Removal - Henny Penny 342 Maintenance Manual

Section 2. maintenance
Table of Contents

Advertisement

2-21. FILTER PUMP AND

MOTOR REMOVAL

(Continued)
Figure 2-74
2-22. AUTOLIFT
TRANSFORMER
REPLACEMENT
(if applicable)
Figure 2-75
Figure 2-76
1003
7. Remove left side panel.
8. Using 9/16" socket or wrenches, remove the bolts and nuts
securing the motor to the bracket and pull pump, motor, and
piping from unit. Figure 2-74.
1. Remove electrical power supplied to unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove control panel.
3. Label and remove wires from transformer. Figure 2-75.
4. Using 3/8" nut-driver or wrench, remove nuts securing
transformer to panel and remove transformer from panel.
Figure 2-76.
5. Install new transformer in reverse order.
Model OFE/OFG/OEA/OGA-341, 342