Henny Penny 342 Maintenance Manual page 18

Section 2. maintenance
Table of Contents

Advertisement

2-17. HEATING ELEMENTS
(ELECTRIC)
(Continued)
Replacement
Figure 2-51
2-18
4. Perform an ohm check on one element at a time, with wires
disconnected. The 2 elements actually have 3 small heating
elements inside the outer plate. It's important to check
between the correct wires to obtain an accurate ohm reading.
The wires are labeled for your convenience. If the resistance
is not within tolerance, replace the element.
Wire Nos.
Voltage
1L1 to 1L1
1L2 to 1L2
1L3 to 1L3
1L1 to 1L1
1L2 to 1L2
1L3 to 1L3
1. Drain the shortening from the frypot
2. Remove the high limit bulb holder from the heating
element inside the frypot. See High Limit Temperature
Control-Electric Section.
3. Using a Phillip's-head screwdriver, remove the screws
securing the element to the element hinges. Figure 2-51.
4. Pull element from fryer and replace with new element,
following steps in reverse order.
. Connect the power cord to the wall receptacle or close wall
5
circuit breaker.
Heating elements should never be energized without
shortening in the frypot, or damage to the elements could
result.
6. Replace the shortening in the frypot, and unit is ready for
operation.
Model OFE/OFG/OEA/OGA-341, 342
Wattage
208
11000
208
11000
208
11000
240
11000
240
11000
240
11000
Ohms (cold)
11.7
11.7
11.7
15.7
15.7
15.7
1003