The controls have four programming levels, a first level mode, a
second level mode, a third level mode, and a special program
mode. In each level, pressing the set switch advances through
the programmable items. Program mode can be entered at
anytime except during an alarm. The left display describes the
item being programmed. The right display shows the item set-
ting and can be changed by pressing the right Up and Down
Switches.
The Low Level Program Mode allows the operator to program
the "global" set point temperature (if enabled), cook and hold
time, and set up to four alarms for the selected product.
1. Press and hold Set and Temperature Switch for at least
five seconds. A tone will sound, and the left display shows
"OF" and the right display shows the set point temperature.
The temperature LED and all product indicator LED's flash.
2. Press the right Up and Down Switches to program
desired set point temperature for all products.
3. Press the set switch and left display shows "Slct" and
the right display shows "Prod". The product LED also
flashes.
4. Press either the left or right Up and Down Switches to select
a product to program, and the LED will be lit next, to the
desired product.
5. Press the set switch and the time LED flashes. The left
displays shows "Fry" and the right display shows the cook
time. Pressing the right Up and Down Switches adjusts the
cook time.
6. Press the set switch and the time LED continues to flash.
The left display shows "Hold," the right display shows the
hold time and can be adjusted with the right Up and Down
Switches.

Advertisement

loading

Summary of Contents for Henny Penny OE/OG 301

  • Page 1 The controls have four programming levels, a first level mode, a second level mode, a third level mode, and a special program mode. In each level, pressing the set switch advances through the programmable items. Program mode can be entered at anytime except during an alarm.
  • Page 2 7. Press the set switch and the alarm LED flashes. The left display shows “AL 1”) the right display shows the alarm time and can be adjusted with the right Up and Down Switches. 8. Repeat step 8 for alarms 2,3, and 4. 9.
  • Page 3 4-3. I 8. Also, with the Product LED flashing, pressing the right Up and Down Switches will access the Idle Mode parameters. The idle LED will be flashing, the left display will continue to show “Slct” and the right display shows “Prod.”...
  • Page 4 3. Press the Set Switch and the left display flashes “Prob” and “Calib.” The right display shows the actual pot temperature, and the right Up and Down Switches are used for calibration. 4. Press the Set Switch and the left display flashes “AL” and “dur.”...