2-13. DRAIN MICROSWITCH Upon turning the drain handle, the drain microswitch should
REPLACEMENT
Figure 2-32
Figure 2-33
2-14. FILTER SWITCH
REPLACEMENT
Figure 2-34
2-12
"open", cutting off the pilot flame. This will prevent the fryer
from heating while shortening is being drained from the frypot.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. The following check should be made to determine if the drain
microswitch is defective.
a. Remove the two screws and nuts securing the microswitch
to the drain rod valve bracket, and remove microswitch.
Figure 2-32.
b. Remove wires from the switch. Figure 2-33.
c. Check for continuity across the two outside terminals of the
drain switch. If the circuit is open, the drain switch is
defective. The circuit opens by pressing on the actuator of
the microswitch.
3. If defective, replace switch in reverse order.