Henny Penny 342 Maintenance Manual page 3

Section 2. maintenance
Table of Contents

Advertisement

2-3. HIGH TEMPERATURE
LIMIT CONTROL
(Gas Units) (Continued)
Replacement
Figure 2-6
Figure 2-7
Figure 2-8
1003
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. If the tube is broken or cracked, the control opens, shutting
off electrical power to the heat circuit. The control cannot be
reset, and it continuously clicks when pushed.
2. Drain the shortening from the frypot and discard. A substance
from the tube could contaminate the shortening.
3. Remove the control panel.
4. Using a 5/16" wrench, loosen small inside screw nut on
capillary tube. Figure 2-6.
5. Using a 11/16" crows-foot, remove the larger nut securing the
capillary tube to the pot. Figure 2-7.
6. Remove the two screws securing the high limit guard and
remove guard. Figure 2-8
7. Straighten the capillary tube inside the frypot, and pull the
capillary tube through the frypot, from behind the control
panel. Remove the defective high limit from the control panel
area.
8. Replace new high limit in reverse order.
To avoid electrical shock or other injury, run the
capillary line under and away from all electrical power
wires and terminals. The tube must never be in such a
position where it could accidentally touch the electrical
power terminals.
Model OFE/OFG/OEA/OGA-341, 342
2-3