J. Existing Masonry Chimney
Type A
CO-AXIAL TO CO-LINEAR
CONNECTOR PART
#923GCL
PIPE LENGTH
(OPTIONAL)
Type C - Up & Out Installation
TOP ADAPTER
RETRO
CONNECTOR
90º ELBOW
DIRECT
VENT PIPE
Figure 5.24
CHIMNEY LINER
TERMINATION CAP PART
#923GK
3 IN. (76 MM) FLEX LINER
SHOWING TWO 30 FT.
(9 M) SECTIONS OF
FLEX LINER
TERMINATION CAP
PART #SLK-991DA
FLASHING
4 in. (102 mm)
FLEX LINER
*NOTE: In the Commonwealth of Massachusetts, the word damper shall
be replaced with the words fl ue restrictor.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/08
Type B
CO-AXIAL TO CO-LINEAR
CONNECTOR PART #923GCL
PIPE LENGTH
(OPTIONAL)
Type D - Hearth Mount
ALCOVE CLEARANCE TO
COMBUSTIBLES MUST BE
MAINTAINED
CO-AXIAL TO CO-LINEAR
CONNECTOR PART# 923GCL
CHIMNEY LINER TERMINATION
CAP PART #923GK
30 ft. (9 m) OF 3 in. (76 mm)
FLEX LINER EXHAUST
SECTION
THIS SECTION OF THE
CHIMNEY MUST BE SEALED
THE CHIMNEY MUST BE
SEALED FROM THE 4 ft. (1 m)
SECTION TO TERMINATION
USING A SMOKE SHELF OR A
DAMPER. THE SEAL SHOULD
BE 6 in. (152 mm) BELOW THE
END OF THE 4 ft. (1 m) AIR
INTAKE SECTION.
4 ft. (1 m) OF 3 in. (76 mm)
FLEX LINER
"AIR INTAKE SECTION"
CHIMNEY LINER
TERMINATION CAP
PART #923GK
30 FT. (9 m) OF 3 IN. (76 mm)
FLEX LINER
EXHAUST SECTION
THIS SECTION OF
THE CHIMNEY MUST
BE SEALED
CHIMNEY MUST BE SEALED
FROM 4 FT. (1 m) SECTION TO
TERMINATION USING A SMOKE
SHELF OR A DAMPER*.
SEAL SHOULD BE 6 IN. (152 mm)
BELOW END OF 4 FT. (1 m) AIR
INTAKE SECTION.
4 FT. (1 m) OF 3 IN. (76 mm)
FLEX LINER
AIR INTAKE SECTION
21